4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

KDA 3.1-100-3-DY0-U1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.5 (66 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.1-100-3-DY0-U1 is a spindle drive from the KDA Spindle Drives series and features forced cooling with a mounted heatsink blower powered by a 115V AC source. It supports a rated current of 100 Amps, operates on a 300 VDC supply voltage, and functions efficiently in ambient temperatures from 5 to 45 degrees Celsius. This drive includes a second encoder input with synchronous input and accepts 16-bit parallel digital speed command values.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.1-100-3-DY0-U1 is a spindle drive module produced by Bosch Rexroth Indramat within the KDA Spindle Drives series. It serves as the power stage between a machine controller and an AC spindle motor, converting energy from the common DC bus into controlled three-phase output while monitoring speed feedback. In automated machining cells, the module supports closed-loop spindle positioning and controlled acceleration for milling, drilling, and turning equipment. Because it works from a shared DC link, it fits machine architectures that centralize incoming power and distribute it to individual axes.

The drive uses a regulated link voltage of 300 VDC, and its power section is rated for a continuous output of 100 A, allowing medium-frame main spindles to operate without derating. An internal auxiliary supply of 115 V/50-60 Hz powers the heat sink blower, so the cooling hardware remains electrically separate from the DC bus during operation. Thermal management uses forced cooling, and the unit is intended for ambient temperatures from 5 to 45 °C when cabinet airflow is maintained. This arrangement supports continuous spindle service in enclosed machine cabinets where stable semiconductor temperature is important for repeatable operation.

For installation, the unit includes a mounted heat sink blower that directs airflow across the IGBT stack and removes the need for external ducting. The cooling system is suitable for cabinet locations up to 1000 m above sea level, so normal industrial installations at moderate altitude can use the drive without a separate air-handling assembly. Command data reach the drive through a 16-bit digital parallel speed channel, which gives the controller a direct path for reference values. Rotor position can be evaluated through a second encoder input and synchronous input when resolver and incremental feedback signals must be processed at the same time. The separate command and feedback paths allow the drive to coordinate spindle motion with indexed and synchronized machine functions.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
100 A
Second Encoder Input
Second encoder input and synchronous input
Series
3
Speed Command Value
Digital (16 bit parallel)
  • KDA 311003DY0U1

Frequently Asked Questions about KDA 3.1-100-3-DY0-U1:

Q: What type of cooling system is used in the KDA 3.1-100-3-DY0-U1 spindle drive?

A: The KDA 3.1-100-3-DY0-U1 spindle drive features a forced cooling system with a mounted heatsink blower.

Q: What is the rated current of the KDA 3.1-100-3-DY0-U1 spindle drive?

A: This spindle drive operates with a rated current of 100 A, suitable for demanding applications.

Q: What DC supply voltage does the KDA 3.1-100-3-DY0-U1 require?

A: The KDA 3.1-100-3-DY0-U1 is equipped for a DC supply voltage of 300 VDC.

Q: What type of speed command value input does the KDA 3.1-100-3-DY0-U1 accept?

A: A digital 16-bit parallel interface is used for the speed command value on this spindle drive.

Q: What is the maximum installation elevation for the KDA 3.1-100-3-DY0-U1 spindle drive?

A: The maximum allowed installation elevation for this model is 1000 meters above sea level.


Internal Product Review

  • ‘‘The KDA 3.1-100-3-DY0-U1 spindle drive from Bosch Rexroth Indramat stands out with its 100 A rated current and a 300 VDC supply voltage, ensuring strong performance for demanding spindle applications. Forced cooling with a mounted heatsink blower and a 115V/50-60Hz AC source maintains stable operation even in continuous use. This model is ideal for installations up to 1000 meters above sea level, combining reliable control with a digital 16-bit parallel speed command interface.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo