The Bosch Rexroth Indramat KDA 3.1-100-3-D0D-U1 is a spindle drive from the KDA Spindle Drives series with a rated current of 100 Amps and a DC supply voltage of 300 Volts. It features forced cooling with a mounted heatsink blower powered by a 115V AC source at 50-60Hz, and operates within an ambient temperature range of 5 to 45 degrees Celsius. The drive supports digital speed command values with 16-bit parallel input and includes a position command value interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-100-3-D0D-U1 belongs to the KDA Spindle Drives series produced by Bosch Rexroth Indramat. As a spindle drive, it supplies regulated three-phase power to high-speed motorized spindles while monitoring current and velocity loops in real time. Revision 3 hardware incorporates an integrated heatsink blower and multiple digital reference channels so the unit can be placed inside a control cabinet and linked directly to CNC or PLC motion controllers.
This drive is powered from a DC bus of 300 VDC and can deliver a continuous output of 100 A to the spindle windings. A separate heatsink fan is fed by an auxiliary line of 115 V/50-60 Hz; separating the blower supply from the DC link prevents load fluctuations from disturbing the power stage. The heatsink sits on the top edge of the housing and operates with forced cooling, pulling air through the fins to maintain semiconductor junction temperatures during high duty cycles. Reliable operation is specified for ambient temperatures from 5 to 45 °C, so the cabinet must stay inside this range to avoid thermal derating of the current regulator.
The installation altitude is limited to 1000 m above sea level, ensuring the fan’s airflow remains sufficient at reduced air density. Axis commands enter through a dedicated interface that carries the digital position command value, allowing coordinated motion with other axes on the machine. Speed regulation uses a 16-bit parallel digital word, which provides fine resolution for spindle orientation tasks. Because there is no second encoder input, position feedback must be supplied solely by the primary spindle encoder routed to the controller rack, simplifying wiring but requiring careful noise shielding of that single feedback channel.
Frequently Asked Questions about KDA 3.1-100-3-D0D-U1:
Q: What type of cooling does the KDA 3.1-100-3-D0D-U1 spindle drive use?
A: The KDA 3.1-100-3-D0D-U1 spindle drive features forced cooling with a mounted heatsink blower.
Q: What is the rated current of the KDA 3.1-100-3-D0D-U1 spindle drive?
A: This model operates with a rated current of 100 A.
Q: What voltage and frequency is required for the heatsink blower on the KDA 3.1-100-3-D0D-U1?
A: The AC source for the heatsink blower is 115V at 50-60Hz.
Q: What is the maximum installation elevation for the KDA 3.1-100-3-D0D-U1 spindle drive?
A: The KDA 3.1-100-3-D0D-U1 can be installed up to 1000 meters above sea level.
Q: What type of speed command interface does the KDA 3.1-100-3-D0D-U1 support?
A: A digital (16 bit parallel) interface is used for speed command value on this model.