The KDA 3.1-100-3-AQD-U1 is a servo drive with an analog control type and a rated current of 100 A. Manufactured by Bosch Rexroth Indramat, it is part of the KDA Spindle Drives series and features a protection class of IP20. This device supports SERCOS/Analog communication and weighs approximately 23 kilograms.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
KDA 3.1-100-3-AQD-U1 is a modular and versatile spindle drive. Optional features available on the drive include analog ±10 Volt speed command values, additional input for an encoder with 1 Volt sinusoidal output, and an interface for 16-bit parallel position command value inputs. The 300 Volts DC bus voltage for KDA drives is supplied by a connected power module. KDA drives in turn supply output power to connected motors. A power module and multiple KDA drives can be installed in the same enclosure for multi-axis control applications. Connection terminals for the DC bus and motor power are located on the front panel of KDA drives. Current output rating of the KDA 3.1-100-3-AQD-U1 drive is 100 Amps. The continuous current output of the drive unis is 70 Amps. KDA units with IP10 ratings must be installed inside a suitable enclosure.
to ease enclosure design and reduce their cost, Bosch allows use of heat sinks for KDA units that mount outside the enclosure. This configuration ensures that hot air is dissipated outside the enclosure, which helps to manage the internal enclosure temperature. In this way, the enclosures for KDA drives don’t require internal cooling or air conditions systems. To further improve dissipation of heat from the heat sink, a blower is mounted underneath it. This blower for the KDA 3.1-100-3-AQD-U1 drive requires AC input at 115 Volts. The upper ambient temperature limit for KDA drives is 45 ⁰C for operation and 85 ⁰C for storage. The absolute upper temperature limit for derated operation is 55 ⁰C. The permitted humidity level for drive operation is F in accordance with DIN 40 040. Weight of this drive is 17.1 kilograms.
Frequently Asked Questions about KDA 3.1-100-3-AQD-U1:
Q: What is the blower power supply?
A: The blower requires 115 Volts power supply.
Q: What is the continuous current rating of the drive?
A: The continuous current rating of the drive is 70 Amps.
Q: Is the heat sink inside the enclosure?
A: The heat sink is outside the drive enclosure.
Q: What is the permitted humidity level?
A: The permitted humidity level is F as per DIN 40 040.
Q: What is the operating temperature range?
A: The operating temperature is 5 to 45⁰C.