The Bosch Rexroth Indramat KDA 3.1-100-3-A0I-W1 is a spindle drive from the KDA Spindle Drives series, featuring a rated current of 100 Amps and a DC supply voltage of 300 VDC. It uses forced cooling with a mounted heatsink blower, designed for operation in ambient temperatures between 5 and 45 degrees Celsius. The drive includes an incremental encoder output and supports installation up to 1000 meters above sea level.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.1-100-3-A0I-W1 belongs to the KDA Spindle Drives series produced by Bosch Rexroth Indramat. This spindle drive is used in industrial automation to power and control machine-tool spindles, translating motion commands from a CNC controller into regulated three-phase power for the motor. It is suited to applications that need stable speed regulation during cutting, drilling, milling, and other continuous spindle processes. The unit is intended for cabinets where the spindle axis must respond quickly to command changes while maintaining smooth rotation. Series designation 3 identifies the product generation, and the integrated control electronics process speed feedback while managing the attached cooling hardware for continuous duty.

The drive connects to a DC bus at 300 VDC and can deliver a continuous phase current of 100 A, matching the requirements of medium-to-large spindle motors in sustained machining service. An auxiliary supply of 220 V/50-60 Hz powers the heat sink blower, helping maintain stable thermal conditions during high-current operation. Internal logic controls fan operation under forced cooling mode so heat is removed regardless of spindle load. Safe operation is permitted within an ambient range of 5 to 45 °C, and the speed loop accepts an analog command value for closed-loop control. Current limiting is monitored inside the drive so overload conditions can be controlled without interrupting normal spindle regulation.

Mechanical installation is permitted up to 1000 m above sea level without output reduction, supporting use at many plant elevations where cabinet cooling remains within the stated range. The cooling hardware uses a mounted heat sink blower attached directly to the rear panel, which simplifies airflow routing in crowded cabinets and keeps the cooling path close to the power section. Speed references arrive through an analog input channel, and position feedback can be retransmitted through an incremental encoder output to external control systems. That retransmitted signal can be used by supervisory control hardware that needs spindle speed or position information. A second encoder socket is not provided, so multi-encoder applications must be handled by upstream equipment or separate interface hardware.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
Incremental encoder output
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
100 A
Second Encoder Input
Does not feature additional input
Series
3
Speed Command Value
Analogue
  • KDA 311003A0IW1

Frequently Asked Questions about KDA 3.1-100-3-A0I-W1:

Q: What type of cooling does the KDA 3.1-100-3-A0I-W1 spindle drive utilize?

A: The KDA 3.1-100-3-A0I-W1 uses a mounted heatsink blower for cooling with forced air.

Q: What is the rated current for the KDA 3.1-100-3-A0I-W1?

A: This spindle drive operates with a rated current of 100 A for demanding applications.

Q: What is the required DC supply voltage for the KDA 3.1-100-3-A0I-W1?

A: The device runs on a DC supply voltage of 300 VDC during standard operation.

Q: What is the maximum installation elevation for the KDA 3.1-100-3-A0I-W1 spindle drive?

A: It is suitable for installation locations up to 1000 meters above sea level.

Q: What type of speed command value input does the KDA 3.1-100-3-A0I-W1 support?

A: The KDA 3.1-100-3-A0I-W1 accepts speed command values in analogue format.


Internal Product Review

  • ‘‘The KDA 3.1-100-3-A0I-W1 spindle drive from Bosch Rexroth Indramat features a mounted heatsink blower with forced cooling and operates on a 300 VDC supply voltage. The unit delivers a rated current of 100 A, supporting high-performance spindle motor control. This model stands out for its reliable cooling system and robust current capacity.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo