KDA 3.1-100-3-A0D-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-100-3-A0D-U1 is a spindle drive from the KDA Spindle Drives series. It features a rated current of 100 Amps and uses a forced cooling system with a mounted heatsink blower powered by a 115V AC source. This unit operates with a DC supply voltage of 300 VDC and is designed for ambient temperatures from 5 to 45 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-100-3-A0D-U1 spindle drive is manufactured by Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. Installed in a modular CNC cabinet, it converts the shared DC bus into regulated three-phase output for the machine-tool spindle, giving the controller precise authority over rotational speed and torque. As a dedicated axis converter, it links numerical control commands to the electromechanical spindle assembly that performs cutting, drilling, or grinding tasks in automated production lines.
A dedicated auxiliary supply at 115 V/50–60 Hz feeds the internal cooling circuit, allowing airflow to start before the DC link is energized. The power stage references a bus of 300 VDC and can continuously deliver 100 A, a capacity sized for medium-power spindles in machining centers and woodworking lines. Reliable operation is declared for ambient temperatures from 5 to 45 °C, limiting the need for cabinet air-conditioning on most shop floors. The drive may be installed up to 1,000 m above sea level without adjustment, so identical parameter sets can be used across plants at moderate elevations.
Thermal management relies on a mounted heat sink blower that forces air through the rear fin channels; this hardware works with the unit’s forced cooling mode to stabilize semiconductor temperatures during prolonged roughing passes. Speed reference data reach the control board as an analog command, while a parallel interface handles a digital position command value, enabling controllers that separate velocity and interpolation loops. Because the Series 3 hardware does not provide a second encoder input, spindle feedback must be routed through the primary sensor only. This arrangement supports separate control loops while helping the drive maintain stable internal temperatures during extended spindle operation.
Frequently Asked Questions about KDA 3.1-100-3-A0D-U1:
Q: What is the rated current of the KDA 3.1-100-3-A0D-U1 spindle drive?
A: The KDA 3.1-100-3-A0D-U1 spindle drive operates with a rated current of 100 A.
Q: What is the DC supply voltage required for the KDA 3.1-100-3-A0D-U1?
A: This model has a DC supply voltage of 300 VDC.
Q: What type of cooling does the KDA 3.1-100-3-A0D-U1 spindle drive utilize?
A: The KDA 3.1-100-3-A0D-U1 features forced cooling through a mounted heatsink blower.
Q: What kind of speed command value does the KDA 3.1-100-3-A0D-U1 accept?
A: The spindle drive accepts a speed command value in analogue format.
Q: What is the maximum installation elevation for the KDA 3.1-100-3-A0D-U1?
A: This model can be installed at elevations up to 1000 meters above sea level.