The Bosch Rexroth Indramat KDA 3.1-100-3-A00-W1 is a spindle drive from the KDA Spindle Drives series. It features forced cooling through a mounted heatsink blower powered by a 220V AC source and operates with a rated current of 100 Amps. The drive is designed for use at up to 1000 meters above sea level within an ambient temperature range of 5 to 45 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-100-3-A00-W1 is a spindle drive developed by Bosch Rexroth Indramat for the KDA Spindle Drives series. Within a machine tool or production cell, it controls the speed and torque of high-speed spindles, receiving a setpoint from the machine controller while regulating the three-phase motor connected to its output. By housing the power section, control electronics, and an integrated blower in one unit, the product simplifies cabinet layout for metal-cutting, grinding, or woodworking systems that demand precise spindle regulation. The control section also helps maintain steady spindle behavior during changing load conditions in continuous production.
The power section is designed for a continuous output of 100 A, allowing it to drive large-frame spindle motors without derating. A DC link voltage of 300 VDC feeds the inverter stage, matching the standard supply modules used throughout the KDA family. Thermal stability is maintained by a mounted heat sink blower that pulls ambient air directly across the aluminum fins. That blower is energized from an auxiliary source rated at 220 V/50–60 Hz, so it runs independently of the DC bus status. Heat is removed more effectively because the drive employs forced cooling, which helps keep internal components within their operating range during long duty cycles and rapid accelerations.
Environmental limits support reliable installation in rooms kept at 5 to 45 °C; outside this band, the internal temperature monitoring may trigger a shutdown. The unit can be mounted at elevations up to 1000 m above sea level without output reduction, which covers most plant locations. Speed reference data arrive as an analog voltage, allowing legacy CNC controllers to interface without extra fieldbus hardware. Expansion is intentionally limited because the drive ships with no additional interface option and omits a secondary encoder input, so the hardware remains focused on core spindle control rather than optional feedback or communication channels.
Frequently Asked Questions about KDA 3.1-100-3-A00-W1:
Q: What is the rated current of the KDA 3.1-100-3-A00-W1 spindle drive?
A: The KDA 3.1-100-3-A00-W1 spindle drive has a rated current of 100 A, making it suitable for high-power requirements.
Q: How is the KDA 3.1-100-3-A00-W1 spindle drive cooled?
A: This model utilizes a mounted heatsink blower and operates using forced cooling to maintain optimal thermal performance.
Q: What is the required DC supply voltage for the KDA 3.1-100-3-A00-W1 spindle drive?
A: It requires a DC supply voltage of 300 VDC for proper operation.
Q: What type of speed command input does the KDA 3.1-100-3-A00-W1 accept?
A: Speed command values for this drive are provided through analogue signals.
Q: What is the allowable operating temperature range for the KDA 3.1-100-3-A00-W1 spindle drive?
A: Operation is supported within ambient temperatures from 5 to 45 degrees Celsius.