4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

KDA 3.1-050-3-LQS-U1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.5 (30 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.1-050-3-LQS-U1 is a spindle drive from the KDA Spindle Drives series. It features forced cooling with a mounted heatsink blower operating at 115V and supports a serial RS 232 C interface. The drive has a rated current of 50 Amps and operates on a 300 VDC supply voltage, with a maximum installation elevation of 1000 meters above sea level.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.1-050-3-LQS-U1 is a drive module produced by Bosch Rexroth Indramat for the KDA Spindle Drives series. It regulates spindle motors used on machining centers and similar automation cells, converting shared DC-bus energy into smooth variable-speed output for cutting or grinding operations. A mounted heatsink and internal blower allow the unit to be installed inside a protected cabinet while removing the thermal load generated by rapid spindle acceleration and deceleration. In machine tools, that control helps the spindle follow commanded speed changes with less disturbance from cutting load variation.

The power section can deliver a continuous output of 50 A, allowing it to energize medium-frame, high-torque spindles without saturation. It draws its operating energy from a DC link maintained at 300 VDC, so it pairs directly with compatible supply modules that create this bus voltage. Heat is removed through forced cooling, which keeps semiconductor junction temperatures within safe limits during sustained duty cycles. Velocity commands arrive digitally over the SERCOS interface, giving deterministic fiber-optic communication between the CNC controller and the drive. A front-panel serial RS-232-C interface is available for setup and diagnostic access. The communication and cooling arrangement supports repeatable spindle control in applications that cycle frequently between acceleration, steady cutting, and deceleration.

Auxiliary requirements include an external blower feed of 115 V, 50/60 Hz that powers the heatsink fan whenever the unit is enabled. The drive can operate in ambient conditions from 5 to 45 °C without derating, provided cabinet airflow is not obstructed. Installation sites may be situated up to 1000 m above sea level; beyond this height, lower air density reduces cooling efficiency. The integral mounted heatsink blower channels air directly across the fin pack, helping maintain a stable thermal gradient during peak regenerative braking events. Adequate cabinet ventilation remains important because the blower can only remove heat effectively when fresh air reaches the cooling path.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
Serial interface (RS 232 C)
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Series
3
Speed Command Value
SERCOS Interface
  • KDA 310503LQSU1

Frequently Asked Questions about KDA 3.1-050-3-LQS-U1:

Q: What speed command interface does the KDA 3.1-050-3-LQS-U1 spindle drive use?

A: The KDA 3.1-050-3-LQS-U1 supports speed command input via a SERCOS interface for precise spindle speed control.

Q: What is the required DC supply voltage for the KDA 3.1-050-3-LQS-U1?

A: This spindle drive operates with a DC supply voltage of 300 VDC.

Q: How is the KDA 3.1-050-3-LQS-U1 spindle drive cooled during operation?

A: The KDA 3.1-050-3-LQS-U1 provides forced cooling through a mounted heatsink blower.

Q: What is the rated current of the KDA 3.1-050-3-LQS-U1 spindle drive?

A: The rated current for this spindle drive is 50 A, enabling it to handle high-power applications.

Q: What additional interface is available on the KDA 3.1-050-3-LQS-U1 spindle drive?

A: This model includes a serial RS 232 C interface for additional connectivity and communication options.


Internal Product Review

  • ‘‘The KDA 3.1-050-3-LQS-U1 spindle drive from Bosch Rexroth Indramat features a rated current of 50 A and utilizes a SERCOS interface for precise speed command integration. Forced cooling is achieved through a mounted heatsink blower, supported by a 115V/50-60Hz AC source. This drive provides consistent performance in demanding spindle control applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo