4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

KDA 3.1-050-3-LQD-W1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.4 (41 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.1-050-3-LQD-W1 is a spindle drive from the KDA Spindle Drives series. It features a rated current of 50 Amps and operates with a DC supply voltage of 300 VDC. The unit is equipped with a mounted heatsink blower using forced cooling and accepts speed command values via a SERCOS interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.1-050-3-LQD-W1 is a spindle drive produced by Bosch Rexroth Indramat for the KDA Spindle Drives series. In an automation cell the unit modulates DC bus power so machine-tool spindles can accelerate, maintain speed, and decelerate under closed-loop control. By converting the plant’s rectified supply into precise three-phase outputs, it lets cutting, drilling, or grinding equipment follow programmed speed profiles without mechanical clutches. This model belongs to the third hardware generation, giving compatibility with companion motion controllers that share the same cabinet bus structure.

Core electrical parameters define the operating envelope. The internal power section works from a DC bus of 300 VDC, and it can deliver a continuous phase current of 50 A to the spindle motor. Heat produced at this load is removed by a 220 V/50–60 Hz fan that is mounted directly on the rear fin stack. That assembly—specified as a Mounted heatsink blower—teams with the drive’s enclosure channels to provide Forced cooling, keeping semiconductor junction temperatures within limits during rapid duty cycles. With these provisions, the drive sustains full current without derating while supporting fast torque rises demanded by high-speed machining.

Installation constraints are equally important. The electronics remain within specification when ambient air lies between 5 to 45 °C, and performance is guaranteed up to 1000 m elevation where thinner air still permits adequate convection through the blower path. Velocity commands reach the controller over the SERCOS interface, while position loop data can be supplied through a Position command value, digital channel. Together these interfaces allow coordinated spindle orientation and tapping sequences without additional hardware, and the Series 3 architecture lets the unit drop into existing Indramat multi-axis cabinets without rewiring the common 300 V bus.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
Position command value, digital
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Series
3
Speed Command Value
SERCOS Interface
  • KDA 310503LQDW1

Frequently Asked Questions about KDA 3.1-050-3-LQD-W1:

Q: What is the rated current for the KDA 3.1-050-3-LQD-W1 spindle drive?

A: The KDA 3.1-050-3-LQD-W1 spindle drive operates with a rated current of 50 A.

Q: What cooling method is used on the KDA 3.1-050-3-LQD-W1 spindle drive?

A: This spindle drive uses a mounted heatsink blower with forced cooling for temperature management.

Q: Which interface does the KDA 3.1-050-3-LQD-W1 use for speed command values?

A: A SERCOS Interface is used to receive speed command values on this model.

Q: What is the maximum installation elevation for the KDA 3.1-050-3-LQD-W1 spindle drive?

A: The drive is designed for installation elevations up to 1000 meters above sea level.

Q: What voltage and frequency are required for the heatsink blower on the KDA 3.1-050-3-LQD-W1?

A: The AC source required for the heatsink blower is 220V at 50-60Hz.


Internal Product Review

  • ‘‘The KDA 3.1-050-3-LQD-W1 spindle drive from Bosch Rexroth Indramat features a 50 A rated current and a SERCOS interface for precise speed command value control. Forced cooling is managed by a mounted heatsink blower powered at 220V/50-60Hz, supporting stable operation in demanding environments. This drive stands out for its combination of high current capacity and reliable thermal management.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo