The Bosch Rexroth Indramat KDA 3.1-050-3-LQ0-W1 is a liquid-cooled spindle drive from the KDA Spindle Drives series, designed for three axes operation. It operates at a rated current of 50 Amps and a power supply voltage of 3 x 400 V AC. The drive features IP20 protection and SERCOS communication compatibility.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
KDA 3.1-050-3-LQ0-W1 is a Bosch Rexroth main spindle drive. Its product line is KDA. This is a series of drives designed for control of industrial motors from the 1MB and 2AD series. KDA drives dissipate heat via a heat sink mounted on their rear side. The heat sink mounts outside the control enclosure. As a result, the heat generated by KDA drives is conducted out of the enclosure, which helps to maintain ambient temperature within prescribed limits. Furthermore, a blower is installed on the heat sink to improve airflow and increase the rate of heat dissipation. This feature makes KDA drives particularly suitable to applications where maintaining ambient temperature is critical for reliable operation. Depending on requirements, operators can order with 110 to 220 Volts power supply. The blower installed on the KDA 3.1-050-3-LQ0-W1 drive is rated for 220 Volts.
The input frequency for the blower can range from 50 to 60 Hertz. The rated and continuous current ratings for the drive unit are 50 Amps and 35 Amps respectively. The DC bus on the unit carries 300 Volts DC. The control voltage bus operates at 24 Volts DC and its current consumption is 1.2 Amps. KDA drives can support three types of speed control interfaces. The speed control interface on the KDA 3.1-050-3-LQ0-W1 drive is SERCOS, which is a standard for high-speed serial communication over fiber optic cables. Each KDA drive can have a maximum of two auxiliary interfaces. This drive has one interface that can accept 1 Volts sinusoidal inputs from a motor encoder. As the protection category of the drive is IP10, it can be used indoors or when mounted inside a suitable enclosure.
Frequently Asked Questions about KDA 3.1-050-3-LQ0-W1:
Q: What is the operating temperature?
A: The operating temperature is 5 to 45 degrees Celsius.
Q: What is the supply voltage for the heatsink blower?
A: Supply voltage for the heatsink blower is 220 Volts AC.
Q: What is the mounting orientation for the drive?
A: The mounting orientation is vertical.
Q: The drive has a SERCOS interface for speed commands.
A: What is the supply voltage for the heatsink blower?
Q: Which motors can be sued with the drive?
A: Bosch 2AD and 1MB motors can be used with KDA drives.