KDA 3.1-050-3-LQ0-W1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-050-3-LQ0-W1 is a spindle drive from the KDA Spindle Drives series, featuring forced cooling through a mounted heatsink blower. It operates at a rated current of 50 Amps with a DC supply voltage of 300 VDC and supports speed command via SERCOS interface. The unit is designed for ambient temperatures between 5 and 45 degrees Celsius and can be installed up to 1000 meters above sea level.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-050-3-LQ0-W1 is a spindle drive produced by Bosch Rexroth Indramat and assigned to the KDA Spindle Drives series. Designed for cabinet installation, the unit controls the speed and acceleration of AC spindle motors in machining centers, grinders, and similar equipment, helping maintain repeatable surface finishes and shorter cycle times in automated production lines. In multi-axis platforms, it serves as the dedicated spindle channel and operates separately from feed-axis drives.
Electrical energy is delivered to the drive over a DC bus rated at 300 VDC, and this voltage is used by the inverter section to create a three-phase output for the spindle. The current capability is 50 A, so connected motors can draw substantial acceleration and cutting torque without pushing the power stage beyond its thermal limits. To stabilize internal temperatures, the unit relies on forced cooling, and its aluminum body carries a mounted heat sink blower that pulls air directly across the transistor modules. That blower is powered from a separate utility feed of 220 V at 50/60 Hz, which isolates its operation from the DC link and allows continuous airflow even when the intermediate circuit is de-energized.
For correct operation, the surrounding air must stay between 5 to 45 °C, and installation is limited to 1000 m above sea level so cooling performance and dielectric spacing remain predictable. Speed commands enter the controller exclusively through the SERCOS interface, and no additional interface option is included, so all setpoints and diagnostics are routed over this fiber-optic fieldbus. The stated ambient range also requires cabinet mounting that matches the drive’s forced-air path, while the altitude limit helps prevent reduced air density from lowering blower cooling performance.
Frequently Asked Questions about KDA 3.1-050-3-LQ0-W1:
Q: What DC supply voltage does the KDA 3.1-050-3-LQ0-W1 use?
A: The KDA 3.1-050-3-LQ0-W1 spindle drive requires a DC supply voltage of 300 VDC for operation.
Q: What is the rated current of the KDA 3.1-050-3-LQ0-W1 spindle drive?
A: This model provides a rated current of 50 A, supporting demanding spindle drive applications.
Q: How is the KDA 3.1-050-3-LQ0-W1 spindle drive cooled?
A: Forced cooling for the drive is achieved using a mounted heatsink blower supplied by 220V at 50–60Hz.
Q: Which interface is used for speed command input on the KDA 3.1-050-3-LQ0-W1?
A: The KDA 3.1-050-3-LQ0-W1 accepts speed command values via the SERCOS interface.
Q: What is the maximum installation elevation for the KDA 3.1-050-3-LQ0-W1?
A: Operation is supported at installation elevations up to 1000 meters above sea level.