KDA 3.1-050-3-L0I-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-050-3-L0I-U1 is a spindle drive from the KDA Spindle Drives series with a forced cooling mode using a mounted heatsink blower. It operates at a rated current of 50 Amps and supports a DC supply voltage of 300 VDC. The drive can function in ambient temperatures from 5 to 45 degrees Celsius and uses a SERCOS interface for speed command value.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-050-3-L0I-U1 spindle drive is manufactured by Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. Designed as a regenerative power module for high-speed machining spindles, it channels energy from a common DC bus into controlled three-phase output for induction or synchronous motors on CNC equipment. By combining current and velocity regulation with an integrated heat sink blower, the unit serves as the primary actuator where precise spindle speed and consistent torque are required in automated production lines.
Its electrical platform centers on a DC bus rated at 300 VDC, from which the inverter can deliver a continuous phase current of 50 A. Thermal stress is limited by a mounted heat sink blower that draws ambient air across the fin stack, and the blower is energized from an auxiliary supply of 115 V at 50/60 Hz. Because airflow is actively directed, the drive uses forced cooling, allowing full-load operation at cabinet temperatures that would derate passively cooled devices. This arrangement helps maintain stable junction temperatures when the spindle accelerates or decelerates under cyclic cutting loads and reduces the risk of thermal shutdowns during continuous machining shifts.
The drive processes speed references over the SERCOS interface, enabling deterministic motion control alongside axis drives on the same fiber-optic ring. For controllers that require tachometer feedback, an incremental encoder output is provided, while a second encoder input is omitted to simplify wiring. Continuous duty is supported between 5 to 45 degrees Celsius and up to 1000 m above sea level. Within this operating range, the supervisory logic modulates blower duty to match heat generation. These operating limits help the drive maintain stable spindle control during normal temperature changes.
Frequently Asked Questions about KDA 3.1-050-3-L0I-U1:
Q: What is the rated current of the KDA 3.1-050-3-L0I-U1 spindle drive?
A: The KDA 3.1-050-3-L0I-U1 spindle drive operates with a rated current of 50 A.
Q: What is the maximum installation elevation allowed for the KDA 3.1-050-3-L0I-U1?
A: The maximum installation elevation for this spindle drive is 1000 meters above sea level.
Q: What cooling method is used in the KDA 3.1-050-3-L0I-U1 spindle drive?
A: A mounted heatsink blower provides forced cooling for this drive model.
Q: What type of speed command value input does the KDA 3.1-050-3-L0I-U1 support?
A: The drive supports SERCOS interface for speed command value input.
Q: What is the required AC source specification for the heatsink blower on the KDA 3.1-050-3-L0I-U1?
A: The AC source required for the heatsink blower is 115V at 50-60Hz.