KDA 3.1-050-3-DYI-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-050-3-DYI-U1 spindle drive is part of the KDA Spindle Drives series and features a rated current of 50 Amps, using a 300 VDC supply. It is equipped with forced cooling via a mounted heatsink blower and can operate in ambient temperatures from 5 to 45 degrees Celsius. The drive supports digital speed command values and includes a second encoder input with synchronous input capabilities.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-050-3-DYI-U1 is a spindle drive module engineered by Bosch Rexroth Indramat within the KDA Spindle Drives series. The unit converts a fixed DC link into variable three-phase output for controlling asynchronous or synchronous spindle motors used on milling centers, lathes, and grinding machines. By integrating with CNC controllers, it supplies regulated torque and speed so that a production spindle can accelerate quickly, hold a commanded velocity, and decelerate under controlled braking. That control behavior supports machine tools where stable spindle speed is important during load changes.
Internally, the drive is linked to a fixed DC bus of 300 VDC, and from this link it can supply a continuous phase current of 50 A to the connected motor windings. Thermal management relies on a heat sink that is cleared by a rear-mounted blower, and airflow is maintained by forced cooling to keep semiconductor temperatures within limits during heavy duty cycles. The blower itself is powered from an auxiliary line of 115 V AC at 50–60 Hz, eliminating the need for an external low-voltage fan supply. Reliable operation is specified between 5 to 45 °C, allowing the drive to sit inside standard electrical cabinets without supplementary climate control. Speed references arrive as a digital 16-bit parallel word, giving the controller fine resolution over incremental velocity changes at high spindle speeds. This input format also supports fast command updates from compatible CNC hardware.
For installation planning, the module may be mounted up to 1000 m above sea level without derating, so typical factory mezzanines or elevated workshops remain within limits. Diagnostic and feedback functions are handled by an incremental encoder output that mirrors spindle position to the master CNC. A second encoder input permits synchronous feedback from tandem axes or a high-resolution scale. This arrangement allows the drive to process both spindle motion data and an additional synchronized feedback signal within the same housing.
Frequently Asked Questions about KDA 3.1-050-3-DYI-U1:
Q: What type of cooling system does the KDA 3.1-050-3-DYI-U1 spindle drive use?
A: This model features forced cooling using a mounted heatsink blower to ensure efficient thermal management.
Q: What is the rated current capacity of the KDA 3.1-050-3-DYI-U1 spindle drive?
A: The KDA 3.1-050-3-DYI-U1 supports a rated current of 50 A for spindle operation.
Q: What power supply is required for the heatsink blower in the KDA 3.1-050-3-DYI-U1?
A: The heatsink blower operates on a 115V AC supply at 50-60Hz, enabling reliable cooling functionality.
Q: How are speed commands input to the KDA 3.1-050-3-DYI-U1 spindle drive?
A: This spindle drive accepts digital speed command values utilizing a 16-bit parallel interface.
Q: What ambient temperature range is supported by the KDA 3.1-050-3-DYI-U1 spindle drive?
A: The ambient temperature range for safe operation is 5 to 45 degrees Celsius.