KDA 3.1-050-3-DY0-W1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-050-3-DY0-W1 is a spindle drive from the KDA Spindle Drives series, featuring a rated current of 50 Amps and operates with a DC supply voltage of 300 VDC. It uses forced cooling via a mounted heatsink blower powered by a 220V AC source and supports a digital speed command value of 16 bit parallel.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-050-3-DY0-W1 is produced by Bosch Rexroth Indramat within the KDA Spindle Drives series. Delivered as a drive module for motorized spindle axes, it converts a regulated DC bus into variable three-phase output so CNC controllers can command speed and torque with precision. The unit is part of level 3 of the series and is intended for machine-tool spindles that require continuous closed-loop velocity control during cutting, drilling, or grinding operations. This operating role suits equipment that must hold stable spindle speed while cutting conditions change throughout a machining cycle.
The power section is energized from a bus link rated at 300 VDC, and its inverter can supply a continuous phase current of 50 A to the connected motor. Cooling is handled by a mounted heat-sink blower; this fan receives its own AC feed of 220 V / 50-60 Hz, helping keep the drive at a controlled operating temperature while the main converter remains isolated from line harmonics. Speed references arrive through a 16-bit parallel digital input, allowing the controller to issue exact setpoints without analog conversion noise. The module has no additional interface option, so its configuration stays focused on spindle control and direct integration with compatible control hardware.
Thermal limits allow operation in ambient conditions from 5 to 45 °C and at elevations up to 1000 m above sea level. The drive uses forced cooling to maintain internal airflow, which supports stable current regulation when cabinet temperatures vary within the permitted range. Position-related signals can be coordinated through the second encoder input and synchronous input, enabling monitoring needed for spindle orientation and synchronized machine functions. Because no additional interface card is installed, wiring remains more direct and the module fits well in retrofit or modular cabinet layouts where available space may be limited.
Frequently Asked Questions about KDA 3.1-050-3-DY0-W1:
Q: Which cooling method does the KDA 3.1-050-3-DY0-W1 spindle drive use?
A: The KDA 3.1-050-3-DY0-W1 spindle drive utilizes a mounted heatsink blower for efficient cooling.
Q: What is the rated current for the KDA 3.1-050-3-DY0-W1 spindle drive?
A: This spindle drive supports a rated current of 50 A, suitable for medium to high-power applications.
Q: What DC supply voltage does the KDA 3.1-050-3-DY0-W1 need?
A: The KDA 3.1-050-3-DY0-W1 requires a DC supply voltage of 300 VDC for operation.
Q: What power supply is needed for the heatsink blower in the KDA 3.1-050-3-DY0-W1?
A: An AC source of 220V at 50-60Hz is required to operate the heatsink blower on this model.
Q: What is the allowable ambient temperature range for the KDA 3.1-050-3-DY0-W1 spindle drive?
A: The spindle drive works optimally within ambient temperatures of 5 to 45 degrees Celsius.