KDA 3.1-050-3-DQ0-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-050-3-DQ0-U1 is a spindle drive from the KDA Spindle Drives series. It features forced cooling with a mounted heatsink blower and operates with a rated current of 50 Amps and a DC supply voltage of 300 VDC. The spindle drive supports a digital 16-bit parallel speed command and can be used at elevations up to 1000 meters above sea level.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-050-3-DQ0-U1 spindle drive is produced by Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. It is a closed-loop power module that supplies regulated DC energy and velocity commands to induction or synchronous spindle motors used in CNC machining and transfer lines. By converting the shared DC bus voltage into a controlled three-phase output, the unit lets machine controllers vary spindle speed precisely for cutting, drilling, or grinding operations while maintaining torque and surface finish consistency.
Internally, the drive is supplied from a regulated DC link of 300 VDC, and its main power stage is rated to deliver a continuous armature current of 50 A. Spindle velocity is set through a 16-bit digital parallel word, allowing numerical controls to issue high-resolution speed references without analog drift. The control electronics monitor heatsink temperature while an auxiliary blower draws its feed from an AC source of 115 V/50-60 Hz. Because machining spikes can induce rapid thermal buildup, the unit relies on forced cooling to keep semiconductor junctions within safe limits and sustain the full rated current over long duty cycles.
The cooling air is moved by a heatsink-mounted blower that is fastened directly to the aluminum extrusion, eliminating extra ducting inside the electrical cabinet. The electronic design is specified for ambient conditions between 5 to 45 °C, so operation outside that range can require derating or supplemental air conditioning. Installation is permitted up to 1000 m above sea level, ensuring adequate convection in most factory settings without pressure compensation. The drive is shipped with no additional interface option, so all control takes place through the existing parallel command ports and standard Indramat diagnostics.
Frequently Asked Questions about KDA 3.1-050-3-DQ0-U1:
Q: What is the rated current for the KDA 3.1-050-3-DQ0-U1 spindle drive?
A: The KDA 3.1-050-3-DQ0-U1 spindle drive features a rated current of 50 A, allowing it to handle high-load applications.
Q: How is the KDA 3.1-050-3-DQ0-U1 spindle drive cooled?
A: This model uses a mounted heatsink blower with forced cooling to maintain optimal operating temperatures.
Q: What DC supply voltage does the KDA 3.1-050-3-DQ0-U1 spindle drive require?
A: The KDA 3.1-050-3-DQ0-U1 requires a DC supply voltage of 300 VDC for operation.
Q: How is the speed command value input for the KDA 3.1-050-3-DQ0-U1 spindle drive?
A: The speed command value for this spindle drive is provided digitally using a 16-bit parallel interface.
Q: What is the maximum installation elevation for the KDA 3.1-050-3-DQ0-U1 spindle drive?
A: This spindle drive can be installed at elevations up to 1000 meters above sea level.