KDA 3.1-050-3-AYI-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-050-3-AYI-U1 is a spindle drive in the KDA Spindle Drives series and operates with a rated current of 50 Amps. It features a mounted heatsink blower for forced cooling and accepts a DC supply voltage of 300 VDC. The drive supports a second encoder input as well as analog speed command values, and its heatsink blower runs on 115V AC at 50 to 60Hz.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 3.1-050-3-AYI-U1 is a spindle drive manufactured by Bosch Rexroth Indramat and assigned to the KDA Spindle Drives series. It links the machine control to the spindle motor by converting command signals into regulated armature currents, making it a core component for high-speed cutting, drilling, and grinding operations. Its control behavior suits machine tools that need stable spindle speed during load changes and rapid speed transitions between machining steps.
The power section is supplied from a common DC bus at 300 VDC, and the drive can deliver a continuous phase current of 50 A to match medium-power spindle motors. Thermal energy is removed by a mounted heat sink blower that uses its own single-phase supply of 115 V/50–60 Hz. This arrangement provides forced cooling so the internal semiconductor temperature stays within safe limits during prolonged duty cycles. Speed reference enters the controller as an analog value, while a second encoder input and a synchronous input support phase-locked feedback when multiple axes share the same clock domain. For process monitoring and downstream numerical control, the unit also offers an incremental encoder output that retransmits spindle position to external devices.
The drive operates in ambient temperatures from 5 to 45 °C and at mounting heights up to 1000 m above sea level. Within that operating range, the heat sink blower supports continuous operation without reduced cooling performance. The analog speed command interface allows straightforward velocity scaling from legacy CNC hardware. This layout helps the drive fit systems that need predictable spindle regulation in sealed cabinets or open machine frames where stable signal transfer remains important during continuous production.
Frequently Asked Questions about KDA 3.1-050-3-AYI-U1:
Q: What cooling method is used in the KDA 3.1-050-3-AYI-U1 spindle drive?
A: The KDA 3.1-050-3-AYI-U1 features forced cooling using a mounted heatsink blower.
Q: What is the rated output current of the KDA 3.1-050-3-AYI-U1?
A: This spindle drive is rated for 50 amps of output current.
Q: What DC supply voltage does the KDA 3.1-050-3-AYI-U1 require?
A: The device operates with a DC supply voltage of 300 VDC.
Q: What is the maximum recommended installation elevation for this spindle drive?
A: The KDA 3.1-050-3-AYI-U1 supports a maximum installation elevation of 1000 meters above sea level.
Q: What additional interface is included on the KDA 3.1-050-3-AYI-U1 spindle drive?
A: It includes additional interfaces such as an incremental encoder output for feedback and control integration.