4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

KDA 3.1-050-3-A0I-U1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.5 (39 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 3.1-050-3-A0I-U1 is part of the KDA Spindle Drives series and is designed for forced cooling with a mounted heatsink blower that runs on a 115V AC source. This spindle drive has a rated current of 50 Amps and operates with a DC supply voltage of 300 VDC. It features an incremental encoder output and accepts analog speed command values.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 3.1-050-3-A0I-U1 spindle drive is produced by Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. It serves as the power and control interface between a 300 V DC bus and a high-speed machining spindle, regulating torque and speed so that cutting processes remain stable. Internal power electronics shape the motor current according to external setpoints, and an integrated blower removes switching heat so the unit can maintain continuous duty in automated production cells. The drive is suited to machine tools and similar systems that need stable spindle response during changing cutting loads.

The drive draws its operating energy from a DC link rated at 300 VDC, and it can supply up to 50 A of phase current. Its blower motor is fed from a separate single-phase source of 115 V/50/60 Hz, which keeps the cooling circuit independent of the main power stage. Thermal extraction is handled by a mounted heat sink blower that forces ambient air across the fins in a controlled path. Constant airflow is required to keep semiconductor junctions within tolerance during operation. Acceptable ambient conditions are 5 °C to 45 °C, and installation is permitted up to 1000 m above sea level before derating is applied. These limits apply to revision 3 within the KDA series.

Signal integration is accomplished through an incremental encoder output that forwards real-time shaft position data to a master CNC. The encoder signal lets the control system monitor spindle motion during speed regulation and orientation tasks. A second encoder channel is intentionally omitted to reduce wiring complexity. Speed references arrive as an analog voltage, allowing legacy controllers to dictate spindle velocity without digital fieldbuses. That arrangement fits retrofit applications where existing control hardware already provides voltage-based spindle commands. The drive uses forced cooling, so uninterrupted blower operation remains necessary during sustained load.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
Incremental encoder output
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Second Encoder Input
Does not feature additional input
Series
3
Speed Command Value
Analogue
  • KDA 310503A0IU1

Frequently Asked Questions about KDA 3.1-050-3-A0I-U1:

Q: What is the rated output current for the KDA 3.1-050-3-A0I-U1 spindle drive?

A: The KDA 3.1-050-3-A0I-U1 spindle drive operates with a rated current of 50 A, providing strong power for spindle applications.

Q: How is the KDA 3.1-050-3-A0I-U1 spindle drive cooled?

A: The KDA 3.1-050-3-A0I-U1 is cooled using a mounted heatsink blower, supporting forced cooling for efficient thermal management.

Q: What is the required AC source specification for the heatsink blower on the KDA 3.1-050-3-A0I-U1?

A: This model requires an AC source of 115V at 50-60Hz for the heatsink blower operation.

Q: What type of speed command input does the KDA 3.1-050-3-A0I-U1 accept?

A: The KDA 3.1-050-3-A0I-U1 supports analogue speed command values for control input.

Q: What is the maximum allowed installation elevation for the KDA 3.1-050-3-A0I-U1?

A: This drive can be installed at elevations up to 1000 meters above sea level without performance derating.


Internal Product Review

  • ‘‘The KDA 3.1-050-3-A0I-U1 spindle drive from Bosch Rexroth Indramat delivers reliable performance with a rated current of 50 A and a DC supply voltage of 300 VDC. Mounted heatsink blower and forced cooling ensure stable operation within an ambient temperature range of 5 to 45 degrees Celsius. This model stands out for its dependable cooling and strong power output.’’