KDA 3.1-050-3-A00-W1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 3.1-050-3-A00-W1 is a spindle drive from the KDA Spindle Drives series. It operates with a rated current of 50 Amps and runs on a 300 VDC supply voltage. The drive features forced cooling with a mounted heatsink blower powered by a 220V AC source at 50-60Hz and is designed for ambient temperatures from 5 to 45 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat builds the KDA 3.1-050-3-A00-W1 for high-speed machining centers that require precise spindle regulation. The unit belongs to the KDA Spindle Drives series, which interfaces directly with Indramat drive controllers to modulate motor torque and velocity in real time. By converting a regulated DC link into three-phase output, it supplies controllable power to synchronous or induction spindles and keeps cutting speeds stable across varying tool loads.
The drive’s power section is rated for a continuous output of 50 A, allowing it to handle large acceleration currents without derating during sustained duty cycles. Its DC bus is maintained at 300 VDC, a level compatible with Indramat supply modules in multi-axis cabinets. Internal cooling relies on a blower that is powered from an external 220 V AC line, and that blower tolerates mains frequencies of 50–60 Hz, so it functions in international installations without rewiring. Because the fan is mounted directly on the rear heat sink, this heat sink-mounted blower steadily moves air across the IGBT modules and recovery diodes, keeping semiconductor junction temperatures below their design limits. The electronics rack therefore stays free of additional ducting, and the drive can be placed adjacent to other heat-sensitive components.
Thermal management is reinforced by forced cooling, permitting operation in ambient ranges from 5 to 45 °C without supplemental chillers. The drive may be installed up to 1000 m above sea level before altitude derating rules apply. Closed-loop positioning feedback is available through the primary encoder channel only, as there is no additional encoder input and no auxiliary interface card option. Speed reference data enters the control board as an analog speed command, simplifying integration with legacy CNC systems that already output a calibrated ±10 V spindle reference.
Frequently Asked Questions about KDA 3.1-050-3-A00-W1:
Q: What is the rated current capacity of the KDA 3.1-050-3-A00-W1 spindle drive?
A: The KDA 3.1-050-3-A00-W1 spindle drive delivers a rated current of 50 A.
Q: What power supply is needed for the heatsink blower on the KDA 3.1-050-3-A00-W1?
A: This model requires a 220V AC power source for its heatsink blower, operating at 50-60Hz.
Q: What cooling method does the KDA 3.1-050-3-A00-W1 spindle drive use?
A: The KDA 3.1-050-3-A00-W1 adopts forced cooling using a mounted heatsink blower.
Q: How high above sea level can the KDA 3.1-050-3-A00-W1 be installed?
A: The maximum installation altitude for this spindle drive is 1000 meters above sea level.
Q: What type of speed command input does the KDA 3.1-050-3-A00-W1 support?
A: The KDA 3.1-050-3-A00-W1 accepts speed command values in analogue format.