KDA 2.1-150-3-DY0-W1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 2.1-150-3-DY0-W1 is part of the KDA Spindle Drives series and functions as a spindle drive with a rated current of 150 Amps. It uses a mounted heatsink blower with forced cooling and operates with a DC supply voltage of 300 VDC. The unit supports a digital 16 bit parallel speed command value and operates in temperatures from 5 to 45 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 2.1-150-3-DY0-W1 spindle drive is manufactured by Bosch Rexroth Indramat for the KDA Spindle Drives series. Installed in machining centers, it converts the regulated DC bus from an external supply into three-phase output while executing speed commands from the CNC controller. By forming the electrical link between numerical control hardware and the motor spindle, the unit allows precise acceleration, braking, and steady-state rotation during milling, drilling, and grinding operations. It is suited to spindle axes that alternate between rapid speed changes and long periods of continuous rotation.
The drive is energized from a regulated bus of 300 VDC, so cabinet components must be rated for that potential. Its inverter section delivers a continuous output of 150 A, giving the spindle enough torque for heavy metal removal. Thermal energy created by switching losses is extracted through a mounted heat sink blower; this assembly operates in forced cooling mode to keep semiconductor temperatures within design limits. The blower draws power from a dedicated 220 V/50–60 Hz line instead of the DC link, which simplifies fault isolation. The unit is in series 2 and includes no additional interface option, so all user wiring remains on the standard terminal strip of the base model.
For motion control, the speed reference arrives as a 16-bit digital parallel word, and the unit can close a secondary loop through a second encoder input and a synchronous input when higher positioning accuracy is needed. This arrangement supports spindle applications that use supplemental feedback for tighter control during demanding machining cycles. Site conditions are bounded by an ambient range of 5 to 45 °C and mounting up to 1000 m above sea level. Operation outside those limits can require output derating and reduce cooling effectiveness.
Frequently Asked Questions about KDA 2.1-150-3-DY0-W1:
Q: What type of cooling system is used in the KDA 2.1-150-3-DY0-W1 spindle drive?
A: The KDA 2.1-150-3-DY0-W1 uses a mounted heatsink blower with forced cooling for thermal management.
Q: What is the rated current for the KDA 2.1-150-3-DY0-W1?
A: This spindle drive operates with a rated current of 150 A, supporting demanding spindle applications.
Q: What is the required DC supply voltage for this model?
A: The KDA 2.1-150-3-DY0-W1 accepts a DC supply voltage of 300 VDC for its operation.
Q: What type of speed command input does the KDA 2.1-150-3-DY0-W1 use?
A: A digital 16-bit parallel input is used for the speed command value on this spindle drive.
Q: What is the maximum recommended installation elevation for the KDA 2.1-150-3-DY0-W1?
A: It can be installed at elevations up to 1000 meters above sea level without de-rating.