The Bosch Rexroth Indramat KDA 2.1-150-3-DP0-U1-115 is a spindle drive from the KDA Spindle Drives series. It operates with a rated current of 150 Amps and uses a forced cooled heatsink blower supplied with 115V at 50–60Hz. The drive supports a digital 16-bit parallel speed command and provides an ambient temperature range of 5 to 45 degrees Celsius.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 2.1-150-3-DP0-U1-115 is a Bosch Rexroth Indramat controller in the KDA Spindle Drives series. It energizes machine-tool spindles by converting a fixed DC link into regulated three-phase current that follows digital speed references from the CNC. The integrated heat sink blower and dual encoder paths help the motor maintain its commanded velocity during high-speed cutting and drilling cycles in automated lines. This arrangement supports closed-loop spindle control where speed stability must be maintained as the mechanical load changes during machining.

It delivers a continuous output of 150 A while operating from a 300 V DC bus supplied by the central converter section. The mounted heat sink blower is powered by a dedicated 115 V/50–60 Hz line, so airflow remains available independently of the DC link. Speed references arrive through a digital 16-bit parallel interface, and diagnostics can be viewed through an analog monitor with a range of 0 to +10 V. That monitor channel can sink up to 5 mA, and external signal outputs are limited to 50 mA. A second encoder input is available for additional spindle or motor feedback, and the primary motor encoder connects through a 15-pin X3 plug. No additional interface options are fitted, which keeps cabinet wiring straightforward.

Acceptable ambient conditions span 5 to 45 °C, and the drive can be mounted up to 1000 m above sea level without derating. The incremental encoder channel tolerates ±15 V signals, while the electronics provide +5 V to power the spindle feedback. Forced cooling keeps semiconductor temperatures within normal operating limits during sustained spindle duty. The feedback and monitor connections support stable speed regulation and continuous operating supervision during spindle service.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Analog Output Range
0 to +10 V (max 5 mA)
Blower Supply Frequency
50–60 Hz
Cooling
Mounted Heatsink Blower
Cooling Method
Forced Cooled by Heatsink Blower
Cooling Mode
Forced Cooling
DC bus voltage
300 V
DC Supply Voltage
300 VDC
Incremental Encoder Input (max Voltage)
±15 V
Max Installation Elevation
1000M above sea level
Motor Feedback Connector
15-pin (X3)
Product Type
Spindle Drive
Rated Current
150 A
Second Encoder Input
For spindle feedback or add. motor feedback
Series
2
Signal Output Max Current
50 mA
Speed Command
Digital 16-bit parallel
Speed command value
Digital (16 bit parallel)
Spindle Feedback Supply
+5 V
  • KDA 2.1 150 3 DP0 U1 115
  • KDA 2.11503DP0U1115
  • KDA- 2.1-150-3-DP0-U1-115

Frequently Asked Questions about KDA 2.1-150-3-DP0-U1-115:

Q: What is the rated current for the KDA 2.1-150-3-DP0-U1-115 spindle drive?

A: The KDA 2.1-150-3-DP0-U1-115 has a rated current of 150 A, which is suitable for high power spindle applications.

Q: What is the required DC supply voltage for the KDA 2.1-150-3-DP0-U1-115?

A: This model operates with a DC supply voltage of 300 VDC, allowing for stable and consistent performance.

Q: How is the KDA 2.1-150-3-DP0-U1-115 spindle drive cooled?

A: Forced cooling is provided by a mounted heatsink blower, which helps dissipate heat during operation.

Q: What is the analog output voltage range for this spindle drive?

A: The analog output range is 0 to +10 V with a maximum current of 5 mA.

Q: What is the ambient temperature range supported by the KDA 2.1-150-3-DP0-U1-115?

A: The ambient operating temperature range is 5 to 45 degrees Celsius for this unit.


Internal Product Review

  • ‘‘The KDA 2.1-150-3-DP0-U1-115 is a Bosch Rexroth Indramat spindle drive with a 150 A rated current. Forced cooling by a heatsink blower and a 300 VDC supply support stable thermal management and strong spindle performance. Digital 16-bit parallel speed command and a second encoder input make the unit especially attractive for precise spindle feedback applications.’’