KDA 2.1-150-3-AQS-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 2.1-150-3-AQS-U1 is part of the KDA Spindle Drives series and functions as a spindle drive with a rated current of 150 Amps. It features forced cooling with a mounted heatsink blower, operates with a DC supply voltage of 300 Volts, and includes a serial interface RS 232 C. The drive supports an ambient temperature range of 5 to 45 degrees Celsius and can be installed up to 1000 meters above sea level.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 2.1-150-3-AQS-U1 spindle drive is produced by Bosch Rexroth Indramat for the KDA Spindle Drives series. Installed between the DC bus and a high-speed spindle motor, it converts supplied energy into controlled three-phase output so machining centers can hold constant surface speed and maintain process accuracy in automated production cells. It is part of generation 2 in the series and is used in milling, drilling, and grinding systems that require rapid acceleration, stable speed regulation, and smooth deceleration under numeric control, where spindle response affects both surface finish and cycle consistency.
Electrical power enters the drive at 300 VDC, and its output stage can deliver a continuous 150 A to the spindle, allowing demanding cutting cycles without voltage sag. Speed reference signals are accepted as analog levels, matching standard CNC control cards and supporting direct integration with common spindle command circuits. Thermal management relies on a heat sink blower that draws ambient air across the fins, and the unit uses forced cooling to keep semiconductor temperatures within limits during extended machining passes and repeated load changes. The blower is powered by a separate 115 V / 50–60 Hz auxiliary supply, so cooling can continue independently of the DC bus after spindle motion is reduced or stopped.
The unit operates in ambient temperatures from 5 to 45 °C, which suits typical indoor industrial environments and enclosed machine installations. Full output is maintained up to 1000 m above sea level, allowing use in most standard plant locations without derating. A front-panel RS-232C serial interface is available for parameter upload and error logging. This connection provides a direct local communication path for reading drive status data and reviewing stored fault information when operating values need to be checked.
Frequently Asked Questions about KDA 2.1-150-3-AQS-U1:
Q: What is the rated current of the KDA 2.1-150-3-AQS-U1 spindle drive?
A: The KDA 2.1-150-3-AQS-U1 spindle drive is rated at 150 A for continuous operation.
Q: What is the required DC supply voltage for the KDA 2.1-150-3-AQS-U1?
A: This spindle drive operates with a DC supply voltage of 300 VDC.
Q: How is the KDA 2.1-150-3-AQS-U1 spindle drive cooled?
A: A mounted heatsink blower provides forced cooling for the KDA 2.1-150-3-AQS-U1.
Q: What type of speed command input does the KDA 2.1-150-3-AQS-U1 accept?
A: The KDA 2.1-150-3-AQS-U1 supports speed command input via an analogue signal.
Q: What AC source is required for the heatsink blower on the KDA 2.1-150-3-AQS-U1?
A: For the heatsink blower, this model uses a 115V AC source at 50-60Hz.