KDA 2.1-150-3-AQ0-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 2.1-150-3-AQ0-U1 is a spindle drive from the KDA Spindle Drives series with a rated current of 150 Amps and a DC supply voltage of 300 Volts. It uses a mounted heatsink blower for forced cooling and operates in ambient temperatures from 5 to 45 degrees Celsius. The drive accepts an analog speed command value and is designed for installations up to 1000 meters above sea level.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat's KDA 2.1-150-3-AQ0-U1 belongs to the KDA Spindle Drives series and is supplied as a dedicated spindle drive for CNC and machining centers. Within an automation rack, it converts a fixed DC bus into three-phase motor power while responding to an external analog speed command. By regulating spindle speed and direction, it forms the link between a motion controller and the high-speed cutting motor, ensuring stable torque delivery during milling, drilling, or grinding tasks.
The drive draws a continuous output of 150 A from a regulated DC bus rated at 300 VDC. Its internal heat sink blower is powered from a separate 115 V/50-60 Hz AC source, so thermal management is independent of the main power stage. The electronics, power transistors, and motor feedback circuits are designed to function across an ambient window of 5 to 45 °C, allowing cabinet placement on most factory floors without auxiliary conditioning. Spindle velocity is commanded through a single-ended analog reference that the control card converts into a sinusoidal output pattern. Operation remains electrically and thermally stable up to the rated current because the forced-air path removes switching and copper losses before they accumulate.
Mechanical installation can be performed at sites situated as high as 1000 m above sea level without derating, which matches typical plant elevations. The aluminum heat sink is paired with a mounted heat sink blower; when the fan starts, it pulls air laterally through the fins in a forced cooling configuration, maintaining device temperature even during long machining cycles. This second-generation hardware carries a streamlined signal board that includes drive-enable and fault-relay contacts, yet it provides no additional interface option for fieldbus expansion, simplifying wiring and reducing cabinet depth for retrofit projects.
Frequently Asked Questions about KDA 2.1-150-3-AQ0-U1:
Q: What is the rated current capacity of the KDA 2.1-150-3-AQ0-U1 spindle drive?
A: This model operates with a rated current of 150 A.
Q: How is the KDA 2.1-150-3-AQ0-U1 spindle drive cooled?
A: The KDA 2.1-150-3-AQ0-U1 uses a mounted heatsink blower for forced cooling.
Q: What is the maximum installation elevation for the KDA 2.1-150-3-AQ0-U1?
A: This spindle drive is designed for locations up to 1000 meters above sea level.
Q: What ambient temperature range is supported by the KDA 2.1-150-3-AQ0-U1 spindle drive?
A: The KDA 2.1-150-3-AQ0-U1 operates within an ambient temperature range of 5 to 45 degrees Celsius.
Q: What type of speed command value does the KDA 2.1-150-3-AQ0-U1 spindle drive accept?
A: The speed command input for this model is an analogue signal.