4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

KDA 2.1-150-3-APD-W1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.3 (34 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 2.1-150-3-APD-W1 is a spindle drive from the KDA Spindle Drives series with a rated current of 150 Amps and a DC supply voltage of 300 VDC. It features forced cooling using a mounted heatsink blower powered by a 220V AC source, and supports a digital position command interface and an analog speed command value. The drive operates in ambient temperatures from 5 to 45 degrees Celsius and can be installed up to 1000 meters above sea level.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 2.1-150-3-APD-W1 is a spindle drive module manufactured by Bosch Rexroth Indramat within the KDA Spindle Drives series. It converts a fixed DC bus into controlled three-phase output for high-speed machine-tool spindles, enabling closed-loop speed and position regulation in automated machining centers. As a series 2 drive, it integrates with system controllers that issue analog and digital commands, providing the active power stage between the central supply unit and the motor. The module is intended for spindle applications that require stable torque delivery during acceleration, cutting, and speed transitions.

Its internal power section is energized from a DC link rated at 300 VDC, and it can deliver a continuous current of 150 A, so the connected spindle can produce substantial torque without drive saturation. The heat sink blower runs from an auxiliary AC source of 220 V at 50/60 Hz, which keeps the cooling circuit separate from the main switching section. Operation is permitted between 5 to 45 °C, and installation is permitted up to 1000 m above sea level. Within this operating range, the drive can be used in enclosed industrial cabinets where dependable thermal performance is required during sustained spindle operation.

Thermal management is handled by a mounted heat sink blower, which forces ambient air directly across the fins. This forced cooling method helps keep semiconductor junction temperatures within their intended range during rapid load changes. Control channels accept an analog speed command value for real-time velocity reference, and a second encoder input allows simultaneous spindle feedback or additional motor feedback. This arrangement supports accurate synchronization with external axes during spindle orientation, threading, and other coordinated machine movements.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
Position command value, digital
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
150 A
Second Encoder Input
For spindle feedback or add. motor feedback
Series
2
Speed Command Value
Analogue
  • KDA 211503APDW1

Frequently Asked Questions about KDA 2.1-150-3-APD-W1:

Q: What is the rated current for the KDA 2.1-150-3-APD-W1 spindle drive?

A: The KDA 2.1-150-3-APD-W1 operates with a rated current of 150 A for spindle control.

Q: What DC supply voltage is required by the KDA 2.1-150-3-APD-W1?

A: This spindle drive requires a DC supply voltage of 300 VDC.

Q: How is the KDA 2.1-150-3-APD-W1 spindle drive cooled?

A: It utilizes a forced cooling system with a mounted heatsink blower for temperature management.

Q: What is the maximum installation elevation for the KDA 2.1-150-3-APD-W1?

A: The maximum installation elevation for this unit is 1000 meters above sea level.

Q: What type of speed command value does the KDA 2.1-150-3-APD-W1 use?

A: Analogue speed command values are supported on this spindle drive for speed regulation.


Internal Product Review

  • ‘‘The KDA 2.1-150-3-APD-W1 spindle drive from Bosch Rexroth Indramat features a rated current of 150 A and operates with a reliable 300 VDC supply voltage. Forced cooling via a mounted heatsink blower ensures dependable thermal management even at elevated ambient temperatures. The inclusion of both analog speed command and digital position command interfaces makes this drive a solid performer in precision machine tool applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo