KDA 2.1-100-3-L0S-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 2.1-100-3-L0S-U1 is a spindle drive from the KDA Spindle Drives series. It operates with a rated current of 100 Amps and a DC supply voltage of 300 VDC, using a mounted heatsink blower for forced cooling. The drive is equipped with a SERCOS speed command interface and a serial RS 232 C interface, and supports ambient temperatures from 5 to 45 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 2.1-100-3-L0S-U1 belongs to the KDA Spindle Drives series produced by Bosch Rexroth Indramat. In a machining cell, this unit sits between the main power supply and the motorized spindle, converting the intermediate DC bus voltage into three-phase output that regulates torque and velocity with digital feedback. By coordinating acceleration, deceleration, and setpoint tracking, it keeps cutting tools at commanded speeds so material removal rates stay consistent and surface finish remains predictable in automated production lines.
The drive’s DC link operates from 300 VDC, giving the internal power modules enough headroom to generate the sinusoidal output required for high-speed spindles. A continuous output of 100 A supports demanding duty cycles without derating, while the heat sink blower is energized from a separate 115 V / 50/60 Hz source so fan performance is independent of load changes on the DC bus. Velocity references are received over the SERCOS interface, allowing deterministic communication with CNC or PLC motion controllers. Parameter adjustments and diagnostics can also be handled locally through the integrated serial interface (RS-232-C). The omission of a second encoder input keeps feedback wiring simpler when only one position transducer is required for spindle orientation or speed control.
Thermal stability is maintained by a mounted heat sink blower that draws air directly across the power stage. This supports the drive’s forced cooling mode and removes losses generated during continuous current delivery. Reliable operation is specified within an ambient range of 5 to 45 °C, so cabinet air management must keep the enclosure within those limits. Installation is approved up to 1000 m above sea level. The unit is listed as Series 2, indicating component updates over the original release without changing external dimensions or connector locations.
Frequently Asked Questions about KDA 2.1-100-3-L0S-U1:
Q: What is the rated current of the KDA 2.1-100-3-L0S-U1 spindle drive?
A: The KDA 2.1-100-3-L0S-U1 spindle drive operates with a rated current of 100 A.
Q: What DC supply voltage does the KDA 2.1-100-3-L0S-U1 require?
A: This model requires a DC supply voltage of 300 VDC for proper operation.
Q: What type of additional interface does the KDA 2.1-100-3-L0S-U1 offer?
A: The KDA 2.1-100-3-L0S-U1 features a serial interface using RS 232 C for communication.
Q: How is the KDA 2.1-100-3-L0S-U1 spindle drive cooled?
A: Cooling for this spindle drive is provided by a mounted heatsink blower utilizing forced cooling.
Q: What is the maximum installation elevation for the KDA 2.1-100-3-L0S-U1?
A: The maximum installation elevation for this spindle drive is 1000 meters above sea level.