KDA 2.1-100-3-DQS-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 2.1-100-3-DQS-U1 is a spindle drive from the KDA Spindle Drives series, designed with forced cooling using a mounted heatsink blower and an AC source of 115V at 50-60Hz. It offers a rated current of 100 Amps, operates at a DC supply voltage of 300 VDC, and features a digital 16-bit parallel speed command value. The drive includes a serial RS 232 C interface and functions reliably in ambient temperatures from 5 to 45 degrees Celsius at elevations up to 1000 meters above sea level.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 2.1-100-3-DQS-U1 module is built by Bosch Rexroth Indramat for the KDA Spindle Drives series. This unit serves as the dedicated power amplifier that links a constant DC bus to high-speed spindle motors used in milling, drilling, or grinding equipment. By adjusting motor voltage and frequency on demand, it supports rapid speed changes and torque control that are essential for precise material removal, tool change cycles, and positioning moves within automated machine-tool environments. Its role in the drive train allows the spindle to respond quickly to control commands while maintaining stable operation during changing cutting loads.
The drive draws its main energy from a 300 VDC link and can deliver a continuous phase output of 100 A, giving it the current capacity needed for heavy spindle starts and sustained cutting loads. Thermal management is handled by a mounted blower that operates from a dedicated 115 V/50–60 Hz AC source, and air is forced across the external heat sink so internal components remain within normal operating limits during prolonged duty. Speed references arrive as a Digital 16-bit parallel word, allowing controllers to request precise spindle speed without the drift associated with analog signals. The unit uses forced cooling, so the cabinet must provide a clear airflow path at the blower intake and exhaust.
Installation conditions specify an ambient range of 5 to 45 °C, and the permitted altitude is 1000 m above sea level so that cooling performance remains consistent with the intended design envelope. For parameter access and diagnostics, a serial interface (RS-232 C) is available for connection to service software or an operator terminal. The unit is a Spindle Drive and is intended to be paired with dedicated spindle feedback cards and safety circuits rather than with general-purpose servo axes. These operating limits should be observed whenever the drive is installed in enclosed machine cabinets or on production equipment with limited airflow.
Frequently Asked Questions about KDA 2.1-100-3-DQS-U1:
Q: What is the rated current of the KDA 2.1-100-3-DQS-U1 spindle drive?
A: The KDA 2.1-100-3-DQS-U1 supports a rated current of 100 A for spindle drive operation.
Q: What type of cooling system does the KDA 2.1-100-3-DQS-U1 use?
A: This spindle drive is equipped with a mounted heatsink blower for forced cooling.
Q: What is the operating ambient temperature range for the KDA 2.1-100-3-DQS-U1?
A: The KDA 2.1-100-3-DQS-U1 operates within an ambient temperature range of 5 to 45 degrees Celsius.
Q: What AC power source does the KDA 2.1-100-3-DQS-U1 require for its heatsink blower?
A: A 115V, 50-60Hz AC source powers the heatsink blower in this model.
Q: How are speed command values supplied to the KDA 2.1-100-3-DQS-U1 spindle drive?
A: This unit receives speed command values digitally via a 16-bit parallel interface.