KDA 2.1-100-3-D0S-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 2.1-100-3-D0S-U1 is a spindle drive in the KDA Spindle Drives series. It operates with a rated current of 100 Amps and uses a 300 VDC supply voltage. The drive features forced cooling with a mounted heatsink blower and a serial interface RS 232 C.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 2.1-100-3-D0S-U1 is a spindle drive built by Bosch Rexroth Indramat for the KDA Spindle Drives series. It serves as the power and regulation stage between a DC bus and high-speed machining spindles, converting command data into controlled three-phase output. Within an automation cell, this unit coordinates rapid tool rotation and torque delivery, allowing CNC controllers to maintain surface finish and throughput during drilling, milling, or grinding tasks. Because spindle demand can change quickly during cutting, the regulator adjusts output so commanded speed is maintained as tool load varies.
The drive electronics are energized from a 300 VDC supply rail, and the output section can deliver up to 100 A of continuous current to the motor windings. An auxiliary blower is powered from 115 V at 50/60 Hz and moves air across the heat sink to stabilize internal temperature. Thermal extraction uses forced cooling, which supports full current across the allowed load range. Speed reference data arrive as a 16-bit digital parallel word, giving the controller fine resolution over spindle speed changes. This Series 2 variant omits a secondary encoder channel, so feedback is limited to the primary sensor selected by the machine builder. That arrangement suits machines that rely on a single feedback source for closed-loop spindle control.
The drive can operate at ambient temperatures from 5 to 45 °C and at elevations up to 1000 m above sea level without derating. Machine integration is assisted by an RS-232C serial interface, allowing parameter upload, diagnostics, and remote adjustments from a supervisory PC. Cooling hardware includes a mounted heat sink blower fixed to the housing, so separate cabinet airflow is not required for heat removal. With the blower attached directly to the unit, heat is managed locally instead of depending on general cabinet ventilation. This helps the drive fit enclosed machine layouts where external airflow is limited.
Frequently Asked Questions about KDA 2.1-100-3-D0S-U1:
Q: What is the rated current for the KDA 2.1-100-3-D0S-U1 spindle drive?
A: The KDA 2.1-100-3-D0S-U1 spindle drive operates with a rated current of 100 A.
Q: How is the KDA 2.1-100-3-D0S-U1 spindle drive cooled?
A: This drive uses a forced cooling system with a mounted heatsink blower.
Q: What AC voltage and frequency does the heatsink blower of the KDA 2.1-100-3-D0S-U1 require?
A: The AC source for the heatsink blower on this drive is 115V at either 50 or 60 Hz.
Q: What type of speed command value does the KDA 2.1-100-3-D0S-U1 accept?
A: A digital 16-bit parallel speed command value is supported by this spindle drive.
Q: What is the highest installation elevation recommended for the KDA 2.1-100-3-D0S-U1?
A: The maximum installation elevation for this model is 1000 meters above sea level.