4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

KDA 2.1-100-3-AY0-W1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.5 (56 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 2.1-100-3-AY0-W1 is part of the KDA Spindle Drives series and is designed as a spindle drive with a rated current of 100 Amps. It features forced cooling with a mounted heatsink blower powered by a 220V AC source, and operates effectively in ambient temperatures from 5 to 45 degrees Celsius. The drive supports a DC supply voltage of 300 VDC and offers a second encoder input with synchronous input capability.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 2.1-100-3-AY0-W1 spindle drive is produced by Bosch Rexroth Indramat as part of the KDA Spindle Drives series. It operates as a closed-loop power stage that supplies regulated current to high-speed machining and grinding spindles. By converting DC-link energy from the cabinet supply into a controlled three-phase output, it follows velocity commands from the CNC controller and supports stable spindle operation during demanding motion profiles. It is intended for applications that require precise torque delivery and repeatable speed control as spindle load changes during cutting or finishing.

Internally, the drive is powered from a 300 VDC bus, and its output stage is rated for a continuous line current of 100 A, which allows direct use with medium-frame induction or synchronous spindle motors. Thermal management is handled by a mounted heat sink blower. This blower operates from an auxiliary supply of 220 V/50–60 Hz and pushes air across the cooling fins to control transistor temperature. Because airflow is directed through the heat sink rather than the control electronics, the unit uses forced cooling and can maintain thermal performance when cabinet air movement is limited. This cooling arrangement supports continuous operation under sustained spindle load and helps limit thermal drift in the power section.

The drive operates in ambient temperatures from 5 to 45 °C and can be installed at elevations up to 1000 m above sea level without current reduction. Command signals are handled as an analog speed reference. A dedicated interface provides a second encoder input and a synchronous input for master-slave spindle coordination. That arrangement supports coordinated operation in multi-axis machining systems where spindle synchronization must follow an external reference. The design uses series 2 control logic and does not include additional communication ports, so integration relies on the standard voltage command channel and encoder feedback.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
100 A
Second Encoder Input
Second encoder input and synchronous input
Series
2
Speed command value
Analogue
  • KDA 211003AY0W1

Frequently Asked Questions about KDA 2.1-100-3-AY0-W1:

Q: What is the cooling method used on the KDA 2.1-100-3-AY0-W1 spindle drive?

A: The KDA 2.1-100-3-AY0-W1 spindle drive uses a forced cooling system with a mounted heatsink blower.

Q: What is the rated current capacity of the KDA 2.1-100-3-AY0-W1?

A: This model operates with a rated current of 100 A for demanding spindle applications.

Q: What DC supply voltage does the KDA 2.1-100-3-AY0-W1 require?

A: The DC supply voltage required for the KDA 2.1-100-3-AY0-W1 is 300 VDC.

Q: What type of feedback inputs are supported by the KDA 2.1-100-3-AY0-W1?

A: Second encoder input and synchronous input are available on this spindle drive.

Q: What is the maximum installation elevation for the KDA 2.1-100-3-AY0-W1 spindle drive?

A: The KDA 2.1-100-3-AY0-W1 can be installed at elevations up to 1000 meters above sea level.


Internal Product Review

  • ‘‘The KDA 2.1-100-3-AY0-W1 spindle drive from Bosch Rexroth Indramat features a rated current of 100 A and operates with a 300 VDC supply voltage, making it well-suited for demanding spindle motor applications. Forced cooling is managed by a mounted heatsink blower with a 220V/50-60Hz AC source, supporting reliable thermal management. The addition of a second encoder input and synchronous input provides enhanced positioning feedback for precision operations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo