KDA 2.1-100-3-AP0-U1 Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
The Bosch Rexroth Indramat KDA 2.1-100-3-AP0-U1 is a spindle drive from the KDA Spindle Drives series. It operates with a rated current of 100 Amps and uses a 115V AC source for the mounted heatsink blower. The drive features forced cooling and supports a DC supply voltage of 300 VDC.
Internal Product Review
The KDA 2.1-100-3-AP0-U1 is a spindle drive from Bosch Rexroth Indramat's KDA series, featuring a rated current of 100 A and a DC supply voltage of 300 VDC. Its forced cooling system utilizes a mounted heatsink blower powered by a 115V/50-60Hz AC source, ensuring stable operation in demanding environments. This model is well-suited for applications that require consistent performance and efficient thermal management.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 2.1-100-3-AP0-U1 spindle drive is produced by Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. Classified as a spindle drive, it regulates high-speed machining spindles by converting DC bus power into three-phase motor current while exchanging control signals with the numerical controller. Within a multi-axis machining center, it functions as the dedicated converter that drives the tool spindle and processes position feedback for closed-loop automation.
This unit is built in hardware series 2 and operates from a DC bus of 300 VDC, which energizes its inverter stage. A continuous output capability of 100 A allows the drive to supply medium-frame induction or synchronous spindles without derating. Thermal energy from the switching devices is removed through a heat sink-mounted blower; the arrangement is designated as forced cooling, which keeps semiconductor junctions within limits during extended cutting cycles. Speed reference is accepted as an analog command, so ±10 V velocity signals from most CNC controllers connect directly. The configuration includes no additional interface option, reducing cabinet complexity when only standard spindle functions are required.
The blower itself runs from a separate supply of 115 V/50-60 Hz, so the fan circuit requires a protected single-phase feed. Correct operation is specified between 5 to 45 °C; within this range the cooling system maintains stable device temperatures. The drive can be mounted up to 1000 m above sea level without derating because air density remains adequate for heat removal. A second encoder input is available, enabling either high-resolution spindle feedback or an additional motor feedback channel to support dual-loop positioning. Because no auxiliary interface slots are present, any further system expansion must be handled at the controller level.