KDA 2.1-050-3-LPS-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 2.1-050-3-LPS-U1 is a spindle drive from the KDA Spindle Drives series and operates with a rated current of 50 Amps and a DC supply voltage of 300 VDC. It uses forced cooling with a mounted heatsink blower powered by a 115V, 50-60Hz AC source and supports SERCOS speed command values. This drive features a serial RS 232 C interface and a second encoder input for spindle or additional motor feedback.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 2.1-050-3-LPS-U1 spindle drive is manufactured by Bosch Rexroth Indramat as part of the KDA Spindle Drives series. It supplies controlled three-phase power to machine-tool spindles while exchanging motion commands and feedback with numerical controls. By closing the torque and speed loop inside the drive, it helps maintain stable spindle velocity during cutting operations and forwards position data to the controller for coordinated axis movement. The unit draws DC-link energy from an external supply module and includes its own cooling hardware for cabinet installation in production equipment.
Its internal power stage operates from a 300 VDC bus, so the drive requires a compatible upstream supply section. Under continuous duty, it can deliver a motor phase current of 50 A, which suits medium-power spindles used in milling, boring, or grinding machines. Speed reference data is transmitted through the SERCOS interface, providing deterministic fiber-optic communication for real-time setpoints. For service access, a serial interface (RS-232-C) is available for parameter transfer, and the blower is powered by a dedicated 115 V, 50/60 Hz single-phase feed so airflow is available as soon as mains power is present.
Thermal management uses a mounted heat sink blower that moves cabinet air across the drive and supports the internal forced cooling path of the power semiconductors. This arrangement keeps operating temperature within an ambient range of 5 to 45 °C during normal installation conditions. The drive can be installed at elevations up to 1000 m above sea level without output reduction, while higher elevations require current derating. An auxiliary encoder socket accepts a second feedback device for spindle orientation or for an additional motor, and the unit is version 2 within the series while retaining the same mounting dimensions.
Frequently Asked Questions about KDA 2.1-050-3-LPS-U1:
Q: What is the rated current capacity of the KDA 2.1-050-3-LPS-U1 spindle drive?
A: The KDA 2.1-050-3-LPS-U1 spindle drive supports a rated current of 50 A for spindle operation.
Q: What cooling method does the KDA 2.1-050-3-LPS-U1 spindle drive use?
A: This drive features forced cooling using a mounted heatsink blower for thermal management.
Q: How does the KDA 2.1-050-3-LPS-U1 receive its speed command values?
A: It utilizes a SERCOS interface to accept speed command values for precise drive control.
Q: What are the power requirements for the heatsink blower on the KDA 2.1-050-3-LPS-U1?
A: The AC source for the heatsink blower requires 115V at 50-60Hz for operation.
Q: What type of additional interface is available on the KDA 2.1-050-3-LPS-U1 spindle drive?
A: A serial interface (RS 232 C) is provided on this model for additional connectivity needs.