4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

KDA 2.1-050-3-L0D-W1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.5 (59 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 2.1-050-3-L0D-W1 is a spindle drive from the KDA Spindle Drives series. It features a rated current of 50 Amps, a 300 VDC supply voltage, and uses forced cooling with a mounted heatsink blower. The drive supports position command value through a digital interface and SERCOS speed command value, and operates in ambient temperatures from 5 to 45 degrees Celsius.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 2.1-050-3-L0D-W1 belongs to the KDA Spindle Drives series manufactured by Bosch Rexroth Indramat. As a spindle drive, it regulates high-speed rotary axes in machine tools by converting a fixed DC bus into variable three-phase output for the motor while exchanging motion data with upper-level CNC controllers. Its design positions the unit as the drive module that closes the velocity loop and enforces axis limits inside an automated machining cell.

This model is powered from a DC bus of 300 V DC, and that fixed link voltage is the reference from which the inverter stage synthesizes the required spindle waveforms. A continuous output capability of 50 A allows the drive to sustain considerable torque demand without derating during roughing cuts or rapid acceleration. Speed references reach the unit through the SERCOS interface, and this fiber-optic fieldbus transmits setpoints and diagnostic data with deterministic timing. For coarse position synchronization, an auxiliary channel described as a digital position command value is available so a master controller can send stepwise position increments independent of the velocity loop. Internal thermal management relies on an external fan circuit that accepts 220 V at 50 to 60 Hz, so the heat sink blower can run from common facility power even when the DC bus is inactive. A second encoder socket is intentionally omitted, simplifying wiring when only one feedback source is required.

Effective heat removal is achieved through forced cooling that moves air across a mounted heat sink blower, and this arrangement keeps semiconductor temperatures stable during continuous high-load operation. The electronics operate in ambient temperatures from 5 to 45 °C, accommodating most factory climates without supplementary conditioning. Installation is permitted up to 1000 m above sea level, ensuring full current delivery before altitude-related air-density reduction can affect blower performance. The drive should be installed where airflow to the blower remains unobstructed.

AC Source for Heatsink Blower
220V/50-60Hz
Additional Interfaces
Position command value, digital
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Second Encoder Input
Does not feature additional input
Series
2
Speed Command Value
SERCOS Interface
  • KDA 210503L0DW1

Frequently Asked Questions about KDA 2.1-050-3-L0D-W1:

Q: What is the rated current capacity of the KDA 2.1-050-3-L0D-W1 spindle drive?

A: The KDA 2.1-050-3-L0D-W1 operates with a rated current of 50 A for high-demand spindle applications.

Q: What cooling method is used in the KDA 2.1-050-3-L0D-W1 spindle drive?

A: This spindle drive features forced cooling via a mounted heatsink blower for effective thermal management.

Q: What is the AC voltage requirement for the heatsink blower on the KDA 2.1-050-3-L0D-W1?

A: The KDA 2.1-050-3-L0D-W1 accepts an AC source of 220V at 50-60Hz for the heatsink blower.

Q: What is the maximum installation elevation for the KDA 2.1-050-3-L0D-W1 spindle drive?

A: This model can be installed at elevations up to 1000 meters above sea level.

Q: Which interface does the KDA 2.1-050-3-L0D-W1 use for speed command input?

A: Speed command values are received via the SERCOS interface on this spindle drive.


Internal Product Review

  • ‘‘The KDA 2.1-050-3-L0D-W1 is a spindle drive from the Bosch Rexroth Indramat KDA series, featuring a rated current of 50 A and a DC supply voltage of 300 VDC. Efficient forced cooling is achieved with a mounted heatsink blower operating on 220V/50-60Hz, supporting consistent performance in demanding environments. The digital position command value interface and SERCOS speed command capability make this drive a strong choice for precision spindle control applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo