KDA 2.1-050-3-DPD-U1 Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat KDA 2.1-050-3-DPD-U1 is a spindle drive in the KDA Spindle Drives series. It features a mounted heatsink blower with forced cooling and operates at a rated current of 50 Amps with a DC supply voltage of 300 VDC. The drive supports digital position and speed command values and works in ambient temperatures from 5 to 45 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The KDA 2.1-050-3-DPD-U1 spindle drive is produced by Bosch Rexroth Indramat for the KDA Spindle Drives series. It is intended for high-speed machining centers, where it converts a regulated DC link into three-phase spindle power and maintains closed-loop velocity control during cutting cycles. Hardware revision 2 uses digital command paths that suit modern CNC architectures, and the cabinet-ready format fits modular Indramat drive bays used in coordinated spindle systems. That combination suits applications that need repeatable spindle speed, rapid response to command changes, and integration with centralized motion control. This layout allows the drive to be installed with matching supply and control modules in compact machine enclosures.
The power section is supplied from a 300 VDC bus that can be provided by TVM or KVR power modules, and the wiring must support a continuous output of 50 A. Cooling air for the dedicated blower is powered from a separate 115 V/50–60 Hz source, so the cabinet needs an additional single-phase connection for thermal management. The CNC sends speed references over a digital 16-bit parallel channel, which avoids analog drift and supports stable spindle response during speed changes. Because the reference is digital, command resolution remains consistent over cable runs and is not affected by analog offset. Installation is permitted up to 1000 m above sea level before output or duty-cycle derating is required.
Full output is available in ambient temperatures from 5 to 45 °C. A mounted heat sink blower moves air directly across the IGBT modules, and the drive uses forced cooling to limit thermal stress during continuous spindle operation. For position-oriented functions, the control board can process an auxiliary encoder channel together with a digital position command value, allowing the same unit to handle indexing, thread cutting, and tool-change positioning without switching to a different drive platform. This is useful when the spindle must align to a known angle before a mechanical sequence begins. The arrangement supports both speed-regulated machining and controlled spindle stopping at defined angular positions.
Frequently Asked Questions about KDA 2.1-050-3-DPD-U1:
Q: What is the rated current of the KDA 2.1-050-3-DPD-U1 spindle drive?
A: The KDA 2.1-050-3-DPD-U1 supports a rated current of 50 A.
Q: What type of cooling does the KDA 2.1-050-3-DPD-U1 employ?
A: This model uses a mounted heatsink blower for forced cooling.
Q: What is the required DC supply voltage for the KDA 2.1-050-3-DPD-U1?
A: The KDA 2.1-050-3-DPD-U1 is designed to operate at a DC supply voltage of 300 VDC.
Q: What ambient temperature range can the KDA 2.1-050-3-DPD-U1 handle?
A: Operation is supported within an ambient temperature range of 5 to 45 degrees Celsius.
Q: What is the purpose of the second encoder input on the KDA 2.1-050-3-DPD-U1?
A: A second encoder input is provided for either spindle feedback or additional motor feedback.