4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

KDA 2.1-050-3-AP0-U1 Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.5 (22 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat KDA 2.1-050-3-AP0-U1 is a spindle drive from the KDA Spindle Drives series. It is rated at 50 Amps and uses a 300 VDC supply voltage. The unit features forced cooling through a mounted heatsink blower and operates within an ambient temperature range of 5 to 45 degrees Celsius.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The KDA 2.1-050-3-AP0-U1 is a spindle drive from Bosch Rexroth Indramat and belongs to the KDA Spindle Drives series. As a closed-loop power module, it supplies and regulates torque for high-speed machine-tool spindles so that speed commands from the CNC controller are translated into precise mechanical rotation within an automated line. A second encoder socket supports spindle feedback or additional motor feedback, allowing the drive to work in closed-loop spindle applications that require accurate speed correction during operation.

In operation, the power section is energized from a DC bus of 300 VDC, and the current path is rated for up to 50 A of continuous load, so compatible inverters and protection devices must be sized accordingly. Thermal management uses a 115 V, 50/60 Hz source that drives the integrated blower mounted directly on the heat sink; this arrangement is identified in the build code as a mounted heat sink blower. Airflow across the fins dissipates switching losses and allows the drive to maintain rated current without derating. Speed reference data arrive as an analog voltage or current signal, which the control board converts into a pulse-width-modulated output for the spindle motor. The field for additional interfaces is blank, so no extra interface option is included on this version.

System designers can integrate the unit into enclosures that use forced cooling, because the blower continuously pulls ambient air between 5 to 45 °C through the heat sink and keeps internal components within safe operating limits. The drive maintains full operation at elevations up to 1000 m above sea level, permitting installation on mezzanine floors or at moderate-altitude facilities without adjustment to current or power limits. The product is Series 2, and the absence of auxiliary communication ports simplifies wiring when only basic analog command and encoder lines are required.

AC Source for Heatsink Blower
115V/50-60Hz
Additional Interfaces
No Additional Interface Option
Ambient Temp Range
5 to 45 Degrees Celsius
Cooling
Mounted Heatsink Blower
Cooling Mode
Forced Cooling
DC Supply Voltage
300 VDC
Max Installation Elevation
1000M above sea level
Product Type
Spindle Drive
Rated Current
50 A
Second Encoder Input
For spindle feedback or add. motor feedback
Series
2
Speed Command Value
Analogue
  • KDA 210503AP0U1

Frequently Asked Questions about KDA 2.1-050-3-AP0-U1:

Q: What cooling method is used in the KDA 2.1-050-3-AP0-U1 spindle drive?

A: The KDA 2.1-050-3-AP0-U1 uses a mounted heatsink blower for cooling, providing forced cooling for its components.

Q: What is the rated current for the KDA 2.1-050-3-AP0-U1 spindle drive?

A: This spindle drive is rated for a maximum current of 50 A during normal operation.

Q: What is the allowable ambient temperature range for the KDA 2.1-050-3-AP0-U1?

A: The ambient temperature range for this model is 5 to 45 degrees Celsius, ensuring reliable performance within this range.

Q: What is the maximum installation elevation specified for the KDA 2.1-050-3-AP0-U1?

A: Installation is permitted up to a maximum elevation of 1000 meters above sea level for this spindle drive.

Q: What AC voltage and frequency are required to power the heatsink blower on this model?

A: The AC source requirement for the heatsink blower is 115V at 50-60Hz.


Internal Product Review

  • ‘‘The KDA 2.1-050-3-AP0-U1 spindle drive from Bosch Rexroth Indramat delivers excellent performance with a rated current of 50 A and a DC supply voltage of 300 VDC. Its forced cooling system, utilizing a mounted heatsink blower powered by a 115V AC source, ensures stable operation within a 5 to 45 degrees Celsius ambient temperature range. This drive stands out for its reliable spindle control and effective thermal management.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo