COVID-19 Update: Wake Industrial is open and available to support your automation needs.

HVE02.2-W018

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
  • MPN: R911280031
  • Stock: In-Stock, Ships 3-5 Days
  • Call for Expedited Shipping and Product Condition Options
The HVE02.2-W018 Power Supply System is manufactured by Rexroth Indramat Bosch. This power supply system has a rated power voltage of 18 and a nominal voltage of 380 to 480V.

Request a Quote Request Repair

Standard Repair Time is 1 - 2 weeks. 4 Day Rush Repair options are available.

HVE02.2-W018

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
  • MPN: R911280031
  • Stock: In-Stock, Ships 3-5 Days
  • Call for Expedited Shipping and Product Condition Options
The HVE02.2-W018 Power Supply System is manufactured by Rexroth Indramat Bosch. This power supply system has a rated power voltage of 18 and a nominal voltage of 380 to 480V.

Request a Quote Request Repair

Standard Repair Time is 1 - 2 weeks. 4 Day Rush Repair options are available.

Warranty
1 Year Wake Industrial Warranty Included
Shipping
Worldwide shipping via DHL, UPS, and Fedex
Exchange
Call to find out about our exchange credit for your defective unit.
Sell Us Your Surplus
Have a HVE02.2-W018 to sell?
To Speak to a sales representative for pricing and lead time:

Product Description

The HVE02.2-W018 is used to operate the drive controller in the drive system. It provides the control voltage supply for all connected controllers and in case of mains failure, it provides the control voltage via its DC bus voltage. It is equipped with monitoring functions that monitor the drive system. This is done by communicating with the drive controllers through the control bus voltage. It is to be used in conjunction with motors of 60 kW mechanical power. When the HVE02.2-W018 is running in generator mode, the regenerated energy is dissipated as heat via the bleeder resistor.

It can be combined with CD bus choke GLD to optimally adjust the power needs of the task at hand. It comes with a protection class of IP 10 which requires it to be mounted in a control cabinet. There should be an air cooling system to ensure the temperature does not exceed 45 degrees. Conditions of use are an operating temperature of 5 to 45 degrees, storage and transport temperature of -30 to 85 degrees, relative humidity of 95%, and an installation altitude of 1000 meters. The input voltage is 3 x 380 … 480 V, frequency is 50/60 Hz, and the power input with maximum load is capped at 500 VA.

The HVE02.2-W018 should not be used in environments that do not meet ambient conditions such as under water and extreme temperature fluctuations. It is exclusively used to supply electricity to HDS and HDD drive controllers. You need to provide additional sensors and actors to control and monitor motors. The HVE02.2-W018 rectifies 3-phase AC voltage into an unregulated DC bus voltage for the connected drive controllers. You can get it from Wake Industrial.

HVE02.2-W018 Documents

  • HVE02.2W018
  • HVE-02.2-W018
  • HVE 02.2 W018

HVE02.2-W018 Technical Specifications

Nominal Voltage: 380 to 480V
Rated Power Voltage: 18