HVE03.2-W030L Bosch Rexroth Indramat
MPN: R911294600
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
33 Seconds
The Bosch Rexroth Indramat HVE03.2-W030L is a power supply unit from the HVE Power Supply Units series with a rated power of 30 kW and a unit width of 150 mm. It features internal air cooling with a built-in blower and has a weight of 16 kilograms. The power supply offers a control voltage output of 300 W and supports a maximum regenerated energy of 100 kWs.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HVE03.2-W030L is a power supply unit manufactured by Bosch Rexroth Indramat within the HVE Power Supply Units series. It is part of series 03 and is built to design version 2. It provides the regulated DC bus energy required by multiple drive controllers and absorbs regenerative power returned during deceleration. By performing these two functions in a single enclosure, the module simplifies cabinet wiring for industrial automation lines that rely on synchronized servo axes and spindle drives.
With a continuous rating of 30 kW, the supply feeds the DC link while drawing only 500 VA at maximum load for its auxiliary circuits. During rapid demand, the bus can deliver 90 kW for 0.3 s or 60 kW for 30 s, enabling short acceleration bursts without a separate booster. The capacitors reach operating voltage in 6 s, and an internal air path with a built-in air blower expels the heat that results from 6 W of loss per delivered kilowatt. A 300 W control-voltage output powers peripheral electronics, while an external capacitor bank up to 100 mF can be added when higher energy storage is required. The unit requires the GLD12 DC-bus choke to attenuate line transients and support smooth regeneration.
Energy that exceeds capacitor storage is dissipated through a brake resistor section rated for 1.5 kW continuously and up to 100 kW in short peaks, allowing the supply to handle emergency stops without external dump resistors. Even when idle, the electronics incur 175 W of basic losses, a figure that helps with enclosure cooling calculations. Up to 100 kWs of regenerated energy can be accepted per cycle before thermal limits are reached. Mechanical integration is straightforward because the housing is 150 mm wide, weighs 16 kg, and mounts beside drives with the airflow of the internal blower left unobstructed.
Frequently Asked Questions about HVE03.2-W030L:
Q: What is the rated power of the Bosch Rexroth Indramat HVE03.2-W030L?
A: The HVE03.2-W030L power supply unit has a rated power of 30 kW for continuous operation.
Q: What cooling method is used by the HVE03.2-W030L power supply unit?
A: This unit utilizes internal air cooling with a built-in blower for temperature management.
Q: What is the DC bus peak power of the HVE03.2-W030L at 400 V?
A: The peak DC bus power for 0.3 seconds at 400 V is 90 kW on this model.
Q: What type of DC bus choke is required for the HVE03.2-W030L?
A: A GLD12 DC bus choke is required for proper operation of this power supply unit.
Q: What is the bleeder peak power capability of the Bosch Rexroth Indramat HVE03.2-W030L?
A: The HVE03.2-W030L is designed with a bleeder peak power capacity of 100 kW for handling regenerative loads.