The Bosch Rexroth Indramat HVE02.2-W018N-RE0 is part of the HVE Power Supply Units series and has a rated power of 18 kW. It supports a maximum connected motor power of 60 kW and provides a control voltage output of 300 W. The power supply uses internal air cooling with a built-in blower and features a charging time of 1.6 seconds.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HVE02.2-W018N-RE0 power supply unit is part of the HVE Power Supply Units Series 02 from Bosch Rexroth Indramat. Designed as a regulated DC source for industrial drive axes, it converts three-phase mains power into a stabilized DC bus and supplies auxiliary control voltage to connected drives. In automated lines, this unit supports up to 60 kW of connected motor load, allowing multiple servo controllers to draw energy from a common supply. This arrangement lets several axes share one supply module while keeping the bus voltage stable in multi-axis systems.
Under nominal line conditions, the unit delivers a rated output of 18 kW while drawing only 500 VA for its own logic and fan circuits. Internal conversion losses are held to 125 W, and the unit has an efficiency value of 7 W/kW of motor power, which helps with cabinet thermal planning. Energy is stored on the DC link by an electrolytic bank with 0.8 mF of capacitance, and the 400 V bus can pass 13 kW to downstream inverters. A 300 W auxiliary tap provides low-voltage control power, and the built-in blower supplies internal air cooling so no external heat sink is required. Initial charging brings the capacitors to full voltage in 1.6 s, which supports quick restarts in cyclic machinery.
For braking and overrunning events, an integrated bleeder resistor dissipates continuous energy up to 1 kW and tolerates surges of 100 kW without triggering a fault. The resistor can absorb a cumulative 70 kWs of regenerated energy before thermal limits are reached. When larger drive groups are linked, external capacitors as large as 10 mF may be connected to the DC link to reduce voltage excursions. This helps the supply manage returned energy during frequent deceleration and other dynamic axis movements. That behavior is useful in indexing lines, transfer systems, and other machines with repeated braking cycles.
Frequently Asked Questions about HVE02.2-W018N-RE0:
Q: What is the rated power output of the HVE02.2-W018N-RE0 power supply unit?
A: The HVE02.2-W018N-RE0 has a rated power output of 18 kW for connected loads.
Q: What is the maximum connected motor power the HVE02.2-W018N-RE0 can handle?
A: This unit supports a maximum connected motor power of 60 kW.
Q: What cooling method is used in the HVE02.2-W018N-RE0 power supply unit?
A: The HVE02.2-W018N-RE0 uses internal air cooling with a built-in blower for heat dissipation.
Q: What is the continuous and peak bleeder power rating for the HVE02.2-W018N-RE0?
A: The built-in bleeder circuit of this unit supports a continuous power of 1 kW and a peak output of 100 kW.
Q: How long does it take to charge the capacitors in the HVE02.2-W018N-RE0 unit?
A: The charging time for the DC bus capacitors in the HVE02.2-W018N-RE0 is 1.6 seconds.