HNL01.1R-0130-N0450-A-480-NNNN Bosch Rexroth Indramat
MPN: R911307259
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
12 Seconds
The Bosch Rexroth Indramat HNL01.1R-0130-N0450-A-480-NNNN belongs to the HNL Mains Chokes series and features a degree of protection rated at IP10. This regenerative supply system choke supports a mains connection voltage of 3 x AC 400 to 480 V with a frequency of 50 or 60 Hz.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HNL01.1R-0130-N0450-A-480-NNNN mains choke is produced by Bosch Rexroth Indramat as part of the HNL Mains Chokes series. In drive lines that return braking energy to the mains, a mains choke sits between the three-phase network and the power converter to curb inrush current, smooth line current, and limit high-frequency harmonics that would otherwise travel back to the plant supply. This model is sized for medium-power automation panels and is intended to operate inside an enclosed cabinet where it supports inverters that return braking energy to the grid. By reducing distortion on the incoming line, it helps the connected drive system draw power more smoothly during acceleration and deceleration.
Electrical compatibility centers on a nominal line of 3 × AC 400–480 V. The coil tolerates supply variation of -15/+10% and works with grid frequencies of 50/60 Hz, so it maintains consistent inductive reactance in both 50 Hz and 60 Hz systems without rewinding. Its enclosure has a protection level of IP10, providing finger-safe coverage while relying on the surrounding cabinet for dust and liquid protection. The unit is design version 1, which identifies the first mechanical layout used for this power class. Because the housing is intended for cabinet installation, higher external protection must be supplied by the enclosure around it.
The unit is part of code 01, so it integrates directly with regenerative converters that return surplus kinetic energy to the mains instead of dissipating it in braking resistors. It comes in the base configuration, with no factory-installed temperature sensors, fuse links, or terminal hoods added to the standard build. That arrangement keeps the mechanical form unchanged for this rating. External monitoring and added protection, when needed, are handled by the surrounding system.
Frequently Asked Questions about HNL01.1R-0130-N0450-A-480-NNNN:
Q: What type of supply system is the HNL01.1R-0130-N0450-A-480-NNNN compatible with?
A: The HNL01.1R-0130-N0450-A-480-NNNN is designed for supply systems with regenerative capability.
Q: What mains connection voltage does the HNL01.1R-0130-N0450-A-480-NNNN support?
A: This mains choke supports a three-phase AC voltage range of 400 to 480 V with a tolerance of -15% to +10% at 50/60 Hz.
Q: What is the degree of protection for the HNL01.1R-0130-N0450-A-480-NNNN mains choke?
A: The HNL01.1R-0130-N0450-A-480-NNNN features a degree of protection rated at IP10.
Q: What is the design version of the HNL01.1R-0130-N0450-A-480-NNNN mains choke?
A: The design version for this mains choke is Version 1.
Q: Are any additional options included with the HNL01.1R-0130-N0450-A-480-NNNN mains choke?
A: No additional options are included with the HNL01.1R-0130-N0450-A-480-NNNN model.