HNL01.1E-0240-N0106-A-500-NPNN Bosch Rexroth Indramat
MPN: R911326641
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
5 Minutes
45 Seconds
The Bosch Rexroth Indramat HNL01.1E-0240-N0106-A-500-NPNN is a choke from the HNL Mains Chokes series with a degree of protection rated at IP10. It supports a mains connection voltage of three-phase AC 380 to 500 Volts at 50 or 60 Hertz and is designed for feeding supply systems.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HNL01.1E-0240-N0106-A-500-NPNN is a passive three-phase mains choke manufactured by Bosch Rexroth Indramat. Installed between the three-phase supply and an inverter, the component adds inductance that limits inrush current, attenuates harmonic content, and smooths line voltage. This helps protect drives and associated control electronics in industrial automation equipment during startup and normal operation. Because the unit is passive, it performs this filtering function without active switching elements or separate control circuitry of its own.
It carries an enclosure protection rating of IP10, so only large foreign objects are excluded and the windings remain open to ambient cooling air. The accepted line range is 3 × AC 380 to 500 V, and the choke operates at standard utility frequencies of 50/60 Hz, which covers most worldwide three-phase grids. The unit is Design Version 1, which indicates the first mechanical layout, terminal geometry, and insulation clearances used for this model. It is also classified as Series 01, and these electrical and mechanical characteristics influence voltage drop, copper loss, and permissible temperature rise during continuous filtering duty. Open airflow around the windings allows heat generated in the copper and core to dissipate naturally during sustained operation.
In operation, the choke is placed on the supply side in the Feeding position, so it experiences the full mains fault level and must tolerate grid disturbances. Because it sits ahead of the inverter, its inductance moderates line disturbances before they reach the input rectifier and DC bus section. The unit is delivered without extra taps, thermal switches, or terminal covers, which keeps the configuration straightforward for standard cabinet installation. It belongs to the HNL Mains Chokes series, where its thermal model and electromagnetic behavior are matched to associated line-side filtering components.
Frequently Asked Questions about HNL01.1E-0240-N0106-A-500-NPNN:
Q: What is the mains connection voltage specification for the HNL01.1E-0240-N0106-A-500-NPNN?
A: The HNL01.1E-0240-N0106-A-500-NPNN operates with a mains connection voltage of 3 x AC 380 to 500 V, accommodating a range of -15% to +10% at 50/60 Hz.
Q: What is the degree of protection for the HNL01.1E-0240-N0106-A-500-NPNN?
A: This product features a degree of protection rated at IP10.
Q: What design version is the HNL01.1E-0240-N0106-A-500-NPNN?
A: The HNL01.1E-0240-N0106-A-500-NPNN belongs to Design Version 1.
Q: Are there any additional options offered with the HNL01.1E-0240-N0106-A-500-NPNN?
A: There are no additional options included with this model.
Q: What type of supply system does the HNL01.1E-0240-N0106-A-500-NPNN use?
A: The supply system for this unit is specified as 'Feeding.'