The Bosch Rexroth Indramat HNF05.1A-500N-R0250-N-A5-NNNN is part of the HNF Mains Filters series and provides a nominal current of 250 Amps. It features IP00 degree of protection and is suitable for regenerative devices only. The filter is designed to meet EMC Category C3 in accordance with DIN EN 61800-3.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat manufactures the HNF05.1A-500N-R0250-N-A5-NNNN mains filter within the HNF Mains Filters series. This passive line component is installed between the utility supply and a regenerative drive package. Because it is a passive device, it remains in the incoming power path during normal operation and does not require its own control logic. In automated machinery, it attenuates high-frequency harmonics produced by inverter switching and provides a low-impedance path for energy recovered during dynamic braking, preventing voltage spikes at the service entrance. By limiting conducted noise, it helps servo axes comply with plant-wide interference emission targets.
The filter carries an IP00 degree of protection, which means its busbars remain uncovered and the unit must be housed inside a closed panel. Its continuous conduction capability is 250 A, supporting sizable drive groups without excess temperature rise or noticeable insertion loss. For electromagnetic compatibility, the product is categorized as C3 under the industrial limits of DIN EN 61800-3, so installation on dedicated plant feeders is expected and additional shielding of motor cables is normally required. These parameters affect wiring layout, thermal planning, and the selection of circuit protection devices.
Design revision 1 denotes the first product revision and keeps the mechanical dimensions aligned with complementary busbar kits supplied for the series. The internal series code 05 groups the module with filters sized for medium-current regenerative axes, aligning impedance and thermal characteristics with factory standards. The supply system is for regenerative devices only, so the filter should be paired exclusively with converters that can return energy to the mains. That operating restriction matters in systems where braking energy is routinely returned to the supply rather than dissipated locally. If it is used with non-regenerative drives, an energy-absorbing resistor or a different filter is required to avoid overvoltage events.
Frequently Asked Questions about HNF05.1A-500N-R0250-N-A5-NNNN:
Q: What is the degree of protection for the HNF05.1A-500N-R0250-N-A5-NNNN mains filter?
A: The HNF05.1A-500N-R0250-N-A5-NNNN mains filter has a protection degree of IP00, which means it does not provide protection against solid objects or water intrusion.
Q: What is the nominal current rating of the HNF05.1A-500N-R0250-N-A5-NNNN mains filter?
A: This model features a nominal current rating of 250 A for demanding electrical applications.
Q: Which EMC category does the HNF05.1A-500N-R0250-N-A5-NNNN mains filter comply with?
A: The HNF05.1A-500N-R0250-N-A5-NNNN conforms to EMC Category C3 according to DIN EN 61800-3.
Q: What type of supply system is the HNF05.1A-500N-R0250-N-A5-NNNN designed for?
A: This filter is suitable only for supply systems with regenerative devices.
Q: What design version is used for the HNF05.1A-500N-R0250-N-A5-NNNN?
A: The design version of the HNF05.1A-500N-R0250-N-A5-NNNN is Version 1.