HDS03.2-W075N-HA07-01-FW Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
55 Seconds
The Bosch Rexroth Indramat HDS03.2-W075N-HA07-01-FW is a drive controller from the HDS Drive Controllers series and the DIAX04 controller family. It features a rated current of 75 Amps and uses a built-in internal air blower for cooling. This model utilizes an analog command communication interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HDS03.2-W075N-HA07-01-FW is a drive controller produced by Bosch Rexroth Indramat and assigned to the HDS Drive Controllers series. Within an automated axis system, the unit supplies regulated power to servo drives and links motion commands from the higher-level PLC to the motor inverter stage. By combining control electronics, the power section, and cooling in a single housing, the module provides closed-loop current and velocity regulation for multiaxis packaging, material-handling, or machining cells. In operation, it bridges higher-level machine commands and low-level drive control so the connected motor can follow commanded speed and current values.
The command communication interface is analog, so the controller expects proportional ±10 V speed or torque references along with enable signals. This allows straightforward integration with legacy PLC cards that output analog voltages. It is part of the DIAX04 controller family, so its parameter structure, diagnostic codes, and SERCOS bus expansion follow that platform. Thermal management uses built-in cooling with an internal air blower that draws cabinet air through the heatsink fins, eliminating the need for external ducting. The power stage is rated for 75 A, allowing the module to process continuous motor RMS current without derating and to support medium-to-large synchronous or induction servomotors in cyclic duty.
The device is Version 2, which indicates a second-generation design with updated gate drivers and faster signal processing than the earlier release. It uses 03 line width within the DIAX rack, so it shares mounting hole positions and connector locations with other controllers of the same frame size. The consistent mechanical format helps the unit fit standard rack layouts where matching controller widths are required.
Frequently Asked Questions about HDS03.2-W075N-HA07-01-FW:
Q: What command communication interface is used by the HDS03.2-W075N-HA07-01-FW drive controller?
A: The HDS03.2-W075N-HA07-01-FW supports analog command communication for system integration.
Q: Which controller family includes the HDS03.2-W075N-HA07-01-FW?
A: This model belongs to the DIAX04 controller family from Bosch Rexroth Indramat.
Q: How is the HDS03.2-W075N-HA07-01-FW cooled during operation?
A: The HDS03.2-W075N-HA07-01-FW features a built-in internal air blower for cooling.
Q: What is the rated current of the HDS03.2-W075N-HA07-01-FW drive controller?
A: This drive controller has a rated current of 75 A, suitable for demanding industrial drives.
Q: What version is the HDS03.2-W075N-HA07-01-FW drive controller?
A: The HDS03.2-W075N-HA07-01-FW is part of version 2 of the HDS03.2 line.