HDS03.2-W100N-HT02-01-FW Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.7 (18 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HDS03.2-W100N-HT02-01-FW is part of the HDS Drive Controllers series and belongs to the DIAX04 controller family. This drive controller features a SERCOS command communication interface and a built-in internal air blower for cooling. It supports a rated current of 100 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDS03.2-W100N-HT02-01-FW is a modular servo drive control unit in the HDS Drive Controllers series produced by Bosch Rexroth Indramat. It slides into a DIAX04 multi-axis rack and regulates power for synchronous or induction motors in packaging lines, material-handling cells, and robotic stages. By converting three-phase supply energy into a stabilized DC link, the controller enables coordinated motion that follows commands from higher-level automation equipment.

The command channel uses the SERCOS fiber-optic interface, establishing 2-ms cycles between the drive and the master controller. A continuous output rating of 100 A lets the module energize medium-to-large axes without derating. Heat is expelled by a internal air blower mounted inside the housing, so extra cabinet fans are unnecessary. As a member of the DIAX04 family it shares backplane power and logic with adjacent units. Hardware identification marked as Line 03 defines mechanical dimensions and connector style.

Firmware resides on removable memory cards, but the hardware itself is classed as version 2, supporting second-generation gate-array logic and updated velocity observers. Within an HDS Drive Controllers series rack it occupies a two-slot position and locks onto common bus bars supplied by Bosch Rexroth Indramat. As an HDS Drive Controller it can parallel additional axes while sharing regenerated energy across the DC link, reducing total power-supply size. No alternate hardware variants are listed, simplifying spare-part management.

Wake Industrial offers same-day shipping options for urgent maintenance needs. Quotes on this model stay valid for 30 days to aid budgeting. For general questions about fault codes or type-code interpretation, customers can use Wake Industrial's free chat tool.

Command Communication Interface
SERCOS
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Cooling Type
Air, internal (with built-in blower)
Function ID Code
2
Line
03
Other Versions
None
Product Group
HDS
Product Type
HDS Drive Controller
Rated Current
100 A
Version
2
  • HDS 03.2-W100N-HT02-01-FW
  • HDS03-2-W100N-HT02-01-FW
  • HDS03.2-W100N-HT02-01
  • HDS032W100NHT0201FW
  • HDS3.2-W100N-HT02-01-FW
  • HDSO3.2-W100N-HT02-01-FW
  • hds03.2-w100n-ht02-01-fw
  • HDS3.2-W1N-HT2-1-FW
  • hds032w100nht0201fw
  • HD503.2-W100N-HT02-01-FW
  • HDS03.Z-W100N-HT02-01-FW
  • HDS03.2-WI00N-HT02-01-FW
  • HDS03.2-W1O0N-HT02-01-FW
  • HDS03.2-W10ON-HT02-01-FW
  • HDS03.2-W100N-HTO2-01-FW
  • HDS03.2-W100N-HT0Z-01-FW
  • HDS03.2-W100N-HT02-O1-FW
  • HDS03.2-W100N-HT02-0I-FW
  • HD5O3.Z-WIOON-HTOZ-OI-FW
  • HDS03.2-W10N-HT02-01-FW
  • HDS03.2-W100N-HT2-01-FW
  • HDS03.2-W100N-HT02-1-FW
  • HDS03.2W100N-HT02-01-FW

Frequently Asked Questions about HDS03.2-W100N-HT02-01-FW:

Q: What communication interface does the HDS03.2-W100N-HT02-01-FW drive controller support?

A: The HDS03.2-W100N-HT02-01-FW drive controller uses SERCOS as its command communication interface.

Q: What is the rated current of the HDS03.2-W100N-HT02-01-FW drive controller?

A: This model has a rated current of 100 A, suitable for high-demand applications.

Q: How is the HDS03.2-W100N-HT02-01-FW drive controller cooled?

A: The cooling method for this unit is a built-in internal air blower.

Q: To which controller family does the HDS03.2-W100N-HT02-01-FW belong?

A: The HDS03.2-W100N-HT02-01-FW is part of the DIAX04 controller family.

Q: What is the version of the HDS03.2-W100N-HT02-01-FW drive controller?

A: This model is designated as version 2 by the manufacturer, indicating its hardware revision.


Internal Product Review

  • ‘‘The HDS03.2-W100N-HT02-01-FW is an HDS Drive Controller from Bosch Rexroth Indramat, featuring a SERCOS command communication interface for seamless integration with advanced automation systems. Its built-in internal air blower ensures efficient thermal management, and the 100 A rated current supports demanding motion control tasks. This unit delivers robust performance and reliable operation for high-power drive applications.’’