The Bosch Rexroth Indramat HDS03.2-W100N-HS78-00-FW is part of the HDS Drive Controllers series and belongs to the DIAX04 controller family. It features a SERCOS command communication interface and has a built-in internal air blower for cooling. This drive controller has a rated current of 100 amps.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDS03.2-W100N-HS78-00-FW drive controller is produced by Bosch Rexroth Indramat and belongs to the HDS Drive Controllers series, which forms the servo-amplifier branch inside the DIAX04 modular platform. Designed to convert rectified DC-bus energy into three-phase motor currents, the unit regulates torque, speed, and position for a single axis in industrial automation cells.

Command data reach the controller across the SERCOS fiber-optic ring, allowing deterministic 2 ms cycle times between drives and the main PLC. Within the DIAX04 family, this model occupies the power slot for medium-to-high current axes; its output stage is rated at 100 A, so appropriate cabling and fuses must be selected. Thermal loads are handled by a built-in internal air blower, which draws cabinet air through dedicated channels instead of relying on external fans. Hardware compatibility is linked to Line 03, meaning backplane connectors and firmware are matched to that generation.

Firmware is loaded on a removable memory card, and the hardware is designated as Version 2, indicating revised IGBT gating and diagnostic circuits compared to the first release. As part of the HDS Drive Controllers series, the unit shares status LED conventions and fault codes with companion supplies, simplifying maintenance. The module is formally classified by Bosch Rexroth Indramat as an HDS Drive Controller, so parameter files created for earlier devices remain compatible. The name Bosch Rexroth Indramat also appears on the identification plate, ensuring traceability in multi-vendor cabinets.

Wake Industrial stocks this controller and can arrange same-day shipping when replacement is urgent. Every purchase includes a 1-year warranty for added procurement security. For general questions about fault codes or type designations, customers may use the free chat tool.

Command Communication Interface
SERCOS
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Cooling Type
Air, internal (with built-in blower)
Function ID Code
78
Line
03
Other Versions
None
Product Group
HDS
Product Type
HDS Drive Controller
Rated Current
100 A
Version
2
  • HDS 03.2-W100N-HS78-00-FW
  • HDS03-2-W100N-HS78-00-FW
  • HDS03.2-W100N-HS78-00
  • HDS032W100NHS7800FW
  • HDS3.2-W100N-HS78-00-FW
  • HDSO3.2-W100N-HS78-00-FW
  • hds03.2-w100n-hs78-00-fw
  • HDS3.2-W1N-HS78--FW
  • hds032w100nhs7800fw
  • HD503.2-W100N-HS78-00-FW
  • HDS03.Z-W100N-HS78-00-FW
  • HDS03.2-WI00N-HS78-00-FW
  • HDS03.2-W1O0N-HS78-00-FW
  • HDS03.2-W10ON-HS78-00-FW
  • HDS03.2-W100N-H578-00-FW
  • HDS03.2-W100N-HS7B-00-FW
  • HDS03.2-W100N-HS78-O0-FW
  • HDS03.2-W100N-HS78-0O-FW
  • HD5O3.Z-WIOON-H57B-OO-FW
  • HDS03.2-W10N-HS78-00-FW
  • HDS03.2-W100N-HS78-0-FW
  • HDS03.2W100N-HS78-00-FW
  • HDS03.2-W100NHS78-00-FW

Frequently Asked Questions about HDS03.2-W100N-HS78-00-FW:

Q: What command communication interface is used by the HDS03.2-W100N-HS78-00-FW drive controller?

A: The HDS03.2-W100N-HS78-00-FW features a SERCOS command communication interface for integration into automation systems.

Q: Which controller family does the HDS03.2-W100N-HS78-00-FW belong to?

A: This drive controller is part of the DIAX04 controller family from Bosch Rexroth Indramat.

Q: How is the HDS03.2-W100N-HS78-00-FW drive controller cooled?

A: The HDS03.2-W100N-HS78-00-FW is cooled using a built-in internal air blower for thermal management.

Q: What is the rated current for the HDS03.2-W100N-HS78-00-FW drive controller?

A: This model offers a rated current capacity of 100 A for its applications.

Q: What version is the HDS03.2-W100N-HS78-00-FW drive controller?

A: The HDS03.2-W100N-HS78-00-FW is identified as Version 2 in its series.


Internal Product Review

  • ‘‘The HDS03.2-W100N-HS78-00-FW is a Bosch Rexroth Indramat HDS Drive Controller from the DIAX04 family, featuring a rated current of 100 A and SERCOS command communication interface. Built-in internal air blower cooling ensures stable thermal performance during demanding applications. This model stands out for its reliable operation in high-power industrial drive systems.’’