The Bosch Rexroth Indramat HDS03.2-W100N-HS75-01-FW is a drive controller from the HDS Drive Controllers series and DIAX04 controller family. It features a rated current of 100 Amps and uses a built-in internal air blower for cooling. The unit supports SERCOS command communication interface.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDS03.2-W100N-HS75-01-FW is a digital drive controller from Bosch Rexroth Indramat in the HDS Drive Controllers series. It converts high-level motion commands into regulated motor current, acting as the bridge between the plant’s mains supply and servo windings. The module fits into multi-axis racks where it coordinates speed, torque, and position across packaging, printing, and material-handling equipment.

Communication with the supervisory PLC is handled through the SERCOS optical interface, delivering deterministic telegrams for synchronized axis updates. On the power side, the controller supplies up to 100 A of continuous output current, letting it drive medium-to-large servomotors without derating. Heat from the IGBT bridge is removed by a Built-in Internal Air Blower, eliminating external cabinet fans. Hardware identification places the unit in the DIAX04 family, ensuring backplane compatibility. The electronics follow hardware Version 2, which adds extended diagnostics. These capabilities let the controller maintain current loops for demanding axes such as rotary knives or pick-and-place gantries.

Occupying the Line 03 slot, the module shares mounting dimensions with earlier Indramat units, allowing retrofits without cabinet rework. Within the wider HDS Drive Controllers series it covers the nominal current tier while retaining identical firmware loading procedures. A factory label from Bosch Rexroth Indramat states that no alternative variants are listed for this code, simplifying spare-parts selection and keeping parameter files consistent across production lines.

Wake Industrial stocks this controller and can arrange same-day shipping. Quotes remain valid for 30 days to aid budgeting. For general questions about fault codes or type-code details, customers may use the free chat tool.

Command Communication Interface
SERCOS
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Cooling Type
Air, internal (with built-in blower)
Function ID Code
75
Line
03
Other Versions
None
Product Group
HDS
Product Type
HDS Drive Controller
Rated Current
100 A
Version
2
  • HDS 03.2-W100N-HS75-01-FW
  • HDS03-2-W100N-HS75-01-FW
  • HDS03.2-W100N-HS75-01
  • HDS032W100NHS7501FW
  • HDS3.2-W100N-HS75-01-FW
  • HDSO3.2-W100N-HS75-01-FW
  • hds03.2-w100n-hs75-01-fw
  • HDS3.2-W1N-HS75-1-FW
  • hds032w100nhs7501fw
  • HD503.2-W100N-HS75-01-FW
  • HDS03.Z-W100N-HS75-01-FW
  • HDS03.2-WI00N-HS75-01-FW
  • HDS03.2-W1O0N-HS75-01-FW
  • HDS03.2-W10ON-HS75-01-FW
  • HDS03.2-W100N-H575-01-FW
  • HDS03.2-W100N-HS7S-01-FW
  • HDS03.2-W100N-HS75-O1-FW
  • HDS03.2-W100N-HS75-0I-FW
  • HD5O3.Z-WIOON-H57S-OI-FW
  • HDS03.2-W10N-HS75-01-FW
  • HDS03.2-W100N-HS75-1-FW
  • HDS03.2W100N-HS75-01-FW
  • HDS03.2-W100NHS75-01-FW

Frequently Asked Questions about HDS03.2-W100N-HS75-01-FW:

Q: What communication interface does the HDS03.2-W100N-HS75-01-FW drive controller use?

A: The HDS03.2-W100N-HS75-01-FW operates with a SERCOS command communication interface.

Q: Which controller family does the HDS03.2-W100N-HS75-01-FW drive controller belong to?

A: This model belongs to the DIAX04 controller family, ensuring compatibility within that product line.

Q: How is the HDS03.2-W100N-HS75-01-FW drive controller cooled?

A: The HDS03.2-W100N-HS75-01-FW features a built-in internal air blower for cooling.

Q: What is the rated current of the HDS03.2-W100N-HS75-01-FW drive controller?

A: This drive controller is rated for a current of 100 A, supporting high power requirements.

Q: What version is the HDS03.2-W100N-HS75-01-FW drive controller?

A: The HDS03.2-W100N-HS75-01-FW is a version 2 model in the HDS Drive Controllers series.


Internal Product Review

  • ‘‘The HDS03.2-W100N-HS75-01-FW HDS Drive Controller from Bosch Rexroth Indramat features a strong built-in internal air blower for efficient cooling and utilizes the SERCOS command communication interface for fast, reliable data exchange. With a rated current of 100 A and part of the DIAX04 controller family, this model is well-suited for demanding industrial drive applications. The combination of high current capacity and effective cooling makes it a dependable choice in automated environments.’’