The Bosch Rexroth Indramat HDS03.2-W075N-HT20-01-FW is a drive controller in the HDS Drive Controllers series. It features SERCOS command communication, a rated current of 75 Amps, and a built-in internal air blower for cooling. This unit is designed as part of the DIAX04 controller family.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDS03.2-W075N-HT20-01-FW belongs to the HDS Drive Controllers series manufactured by Bosch Rexroth Indramat. Installed in DIAX04 racks, this controller bridges incoming three-phase supply power and the servo axes it governs, translating networked motion commands into regulated drive currents for industrial machining centres, packaging lines, and robotic joints.

This version communicates through the SERCOS optical ring, allowing time-synchronised set-point exchange with the master PLC. Within the DIAX04 family it occupies the power slot defined as Line 03, and its output stage is rated for a continuous 75 A so medium-power motors can accelerate without derating. Thermal loads are extracted by a built-in internal air blower, which eliminates dependence on cabinet ventilation and keeps semiconductor temperatures inside permissible limits. Together, these characteristics make the unit suitable for rapid-cycle positioning tasks that demand deterministic bus latency and high peak current.

The hardware is supplied as Version 2, reflecting updated control logic and component revisions that maintain compatibility with newer firmware releases. As part of the HDS Drive Controllers series it shares identical mechanical dimensions, enabling quick swap-out for field service or power upgrading. Integration is further simplified because parameter sets and diagnostics remain consistent across the broader Bosch Rexroth Indramat ecosystem, allowing engineers to manage mixed-capacity axes from one tool. The product classification as an HDS Drive Controller also secures identical mounting points and connector layouts across the range.

Wake Industrial stocks this controller, offers same-day shipping on qualifying orders, and keeps quotations valid for 30 days. Customers can also use the free chat tool to ask about fault codes, type codes, or general specifications.

Command Communication Interface
SERCOS
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Cooling Type
Air, internal (with built-in blower)
Function ID Code
20
Line
03
Other Versions
None
Product Group
HDS
Product Type
HDS Drive Controller
Rated Current
75 A
Version
2
  • HDS 03.2-W075N-HT20-01-FW
  • HDS03-2-W075N-HT20-01-FW
  • HDS03.2-W075N-HT20-01
  • HDS032W075NHT2001FW
  • HDS3.2-W075N-HT20-01-FW
  • HDSO3.2-W075N-HT20-01-FW
  • hds03.2-w075n-ht20-01-fw
  • HDS3.2-W75N-HT2-1-FW
  • hds032w075nht2001fw
  • HD503.2-W075N-HT20-01-FW
  • HDS03.Z-W075N-HT20-01-FW
  • HDS03.2-WO75N-HT20-01-FW
  • HDS03.2-W07SN-HT20-01-FW
  • HDS03.2-W075N-HTZ0-01-FW
  • HDS03.2-W075N-HT2O-01-FW
  • HDS03.2-W075N-HT20-O1-FW
  • HDS03.2-W075N-HT20-0I-FW
  • HD5O3.Z-WO7SN-HTZO-OI-FW
  • HDS03.2-W75N-HT20-01-FW
  • HDS03.2-W075N-HT2-01-FW
  • HDS03.2-W075N-HT20-1-FW
  • HDS03.2W075N-HT20-01-FW
  • HDS03.2-W075NHT20-01-FW

Frequently Asked Questions about HDS03.2-W075N-HT20-01-FW:

Q: What type of command communication interface does the HDS03.2-W075N-HT20-01-FW use?

A: This drive controller uses a SERCOS command communication interface for reliable digital communication with automation systems.

Q: Which controller family is the HDS03.2-W075N-HT20-01-FW compatible with?

A: The HDS03.2-W075N-HT20-01-FW is designed for the DIAX04 controller family, supporting advanced drive functionalities within that system.

Q: What cooling method does the HDS03.2-W075N-HT20-01-FW utilize?

A: Cooling for this drive controller is managed by a built-in internal air blower, allowing for effective heat dissipation during operation.

Q: What is the rated current of the HDS03.2-W075N-HT20-01-FW drive controller?

A: This model provides a rated current of 75 A for high-performance drive applications.

Q: Which version is the HDS03.2-W075N-HT20-01-FW drive controller?

A: The HDS03.2-W075N-HT20-01-FW is manufactured as version 2, distinguishing it from earlier versions in the lineup.


Internal Product Review

  • ‘‘The HDS03.2-W075N-HT20-01-FW is a robust HDS Drive Controller from Bosch Rexroth Indramat, designed for the DIAX04 family and equipped with a SERCOS command communication interface. Its built-in internal air blower ensures efficient cooling, and the unit handles a rated current of 75 A, making it ideal for demanding motion control applications. Overall, this controller delivers reliable performance with advanced connectivity.’’