4.95 based on 202 reviews

🙶 Great response and customer service. Back-order item was shipped sooner than expected as well. 🙷

HDS03.2-W075N-HS98-01-FW Bosch Rexroth Indramat

The Bosch Rexroth Indramat HDS03.2-W075N-HS98-01-FW is a drive controller from the HDS Drive Controllers series and supports a rated current of 75 Amps. This model belongs to the DIAX04 controller family and features a built-in internal air blower for cooling. It utilizes the SERCOS command communication interface.

No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The HDS03.2-W075N-HS98-01-FW is a Bosch Rexroth Indramat HDS Drive Controller featuring a SERCOS command communication interface and a 75 A rated current for demanding automation tasks. The built-in internal air blower ensures reliable cooling, supporting continuous high-performance operation. This drive controller stands out for its robust performance in the DIAX04 family.

Sell Part Have a part to sell?
Warranty Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDS03.2-W075N-HS98-01-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HDS Drive Controllers series. The unit converts setpoint data from a master control system into regulated current for an attached servo or induction motor, allowing precise torque and velocity regulation in multi-axis industrial machinery. It serves as an axis module in a common DC bus rack for coordinated motion in packaging, printing, and material-handling lines. In this role, the controller functions as the power stage for one axis while operating within a shared rack-based drive system.

The controller exchanges cyclic setpoints and status words over the SERCOS fiber-optic interface, so parameter data and real-time position values move deterministically between the drive and the system PLC. That communication path supports synchronized response across multiple axes without separate analog command wiring. A continuous output capacity of 75 A allows the module to supply high-torque motors without external booster hardware. Thermal limits are managed by a built-in air blower, which pulls cabinet air through the heatsink and keeps semiconductor junction temperatures within a safe range. Because the unit belongs to the DIAX04 controller family, it shares a common backplane and power supply arrangement with other compatible axes.

Within the type code, the module is identified as Version 2. This version includes second-generation diagnostic functions and updated parameter memory for the control electronics. The designation Line 03 places the controller in the medium-current range of the series, between lower-current Line 02 units and higher-current Line 04 variants. This placement suits medium-duty axes that need substantial current capacity without moving to the largest power class in the line.

Command Communication Interface
SERCOS
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Installation elevation
1000 M above sea level
Insulation classification
C as per DIN VDE 0110
Line
03
Maximum permissible ambient temperature de-rated
+55° C
Other Versions
None
Permissible ambient temperature range
+5 ... +45° C
Product Type
HDS Drive Controller
Protection category
IP 10 per DIN 40 050
Rated Current
75 A
Storage and transport temperature
-30 ... +85° C
Version
2

Frequently Asked Questions about HDS03.2-W075N-HS98-01-FW:

Q: What type of command communication interface does the HDS03.2-W075N-HS98-01-FW drive controller use?

A: The HDS03.2-W075N-HS98-01-FW is equipped with a SERCOS command communication interface for digital motion control networking.

Q: What is the rated current of the HDS03.2-W075N-HS98-01-FW drive controller?

A: This drive controller provides a rated current of 75 A for its operational output.

Q: How is the HDS03.2-W075N-HS98-01-FW drive controller cooled?

A: Cooling is managed by a built-in internal air blower within the HDS03.2-W075N-HS98-01-FW.

Q: What version is the HDS03.2-W075N-HS98-01-FW drive controller?

A: The HDS03.2-W075N-HS98-01-FW belongs to Version 2 of its product line.

Q: Which controller family does the HDS03.2-W075N-HS98-01-FW belong to?

A: This drive controller is part of the DIAX04 controller family by Bosch Rexroth Indramat.

  • HDS 03.2-W075N-HS98-01-FW
  • HDS03-2-W075N-HS98-01-FW
  • HDS03.2-W075N-HS98-01
  • HDS032W075NHS9801FW
  • HDS3.2-W075N-HS98-01-FW
  • HDSO3.2-W075N-HS98-01-FW
  • hds03.2-w075n-hs98-01-fw
  • HDS3.2-W75N-HS98-1-FW
  • hds032w075nhs9801fw
  • HD503.2-W075N-HS98-01-FW
  • HDS03.Z-W075N-HS98-01-FW
  • HDS03.2-WO75N-HS98-01-FW
  • HDS03.2-W07SN-HS98-01-FW
  • HDS03.2-W075N-H598-01-FW
  • HDS03.2-W075N-HS9B-01-FW
  • HDS03.2-W075N-HS98-O1-FW
  • HDS03.2-W075N-HS98-0I-FW
  • HD5O3.Z-WO7SN-H59B-OI-FW
  • HDS03.2-W75N-HS98-01-FW
  • HDS03.2-W075N-HS98-1-FW
  • HDS03.2W075N-HS98-01-FW
  • HDS03.2-W075NHS98-01-FW
  • HDS03.2W075NHS98-01-FW
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo