4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HDS03.2-W075N-HS47-01-FW Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.6 (59 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
3 Minutes 57 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HDS03.2-W075N-HS47-01-FW is a drive controller in the HDS Drive Controllers series and belongs to the DIAX04 controller family. It has a rated current of 75 Amps, uses a SERCOS command communication interface, and features a built-in internal air blower for cooling.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDS03.2-W075N-HS47-01-FW is a drive controller produced by Bosch Rexroth Indramat. It manages power delivery and motion commands between a DIAX04 servo stack and connected synchronous motors, allowing the drive system to regulate torque, speed, and position during operation. In automated packaging, printing, and material-handling equipment, the controller interprets network commands and converts them into regulated motor action for coordinated axis movement. By combining power electronics and control functions in one unit, it serves as a central element in multi-axis motion systems that require repeatable response and stable axis regulation.

Its command channel uses the SERCOS fiber-optic interface, which supports deterministic cyclic data exchange for synchronized motion on a real-time ring. The controller has a continuous output current of 75 A, which is the maximum phase current available during normal continuous operation under nominal thermal conditions. Cooling is handled by a built-in air blower that moves cabinet air across the heat sink, removing internal losses without external ducting. As part of the DIAX04 platform, the unit uses the same general mounting pattern and connector arrangement found on related controllers in that system.

The unit is part of Line 03, which uses a specific power section layout with standardized bus bars and connector positions. It is Version 2, so the matching parameter set must correspond to that revision of the electrical layout. Classified as an HDS drive controller within the HDS Drive Controllers series, it uses shared diagnostic codes and parameter names that are common across the motion platform. This common structure supports consistent setup and operation when the controller is installed with other compatible modules in the same system.

Command Communication Interface
SERCOS
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Installation elevation
1000 M above sea level
Insulation classification
C as per DIN VDE 0110
Line
03
Maximum permissible ambient temperature de-rated
+55° C
Other Versions
None
Permissible ambient temperature range
+5 ... +45° C
Product Type
HDS Drive Controller
Protection category
IP 10 per DIN 40 050
Rated Current
75 A
Storage and transport temperature
-30 ... +85° C
Version
2
  • HDS 03.2-W075N-HS47-01-FW
  • HDS03-2-W075N-HS47-01-FW
  • HDS03.2-W075N-HS47-01
  • HDS032W075NHS4701FW
  • HDS3.2-W075N-HS47-01-FW
  • HDSO3.2-W075N-HS47-01-FW
  • hds03.2-w075n-hs47-01-fw
  • HDS3.2-W75N-HS47-1-FW
  • hds032w075nhs4701fw
  • HD503.2-W075N-HS47-01-FW
  • HDS03.Z-W075N-HS47-01-FW
  • HDS03.2-WO75N-HS47-01-FW
  • HDS03.2-W07SN-HS47-01-FW
  • HDS03.2-W075N-H547-01-FW
  • HDS03.2-W075N-HS47-O1-FW
  • HDS03.2-W075N-HS47-0I-FW
  • HD5O3.Z-WO7SN-H547-OI-FW
  • HDS03.2-W75N-HS47-01-FW
  • HDS03.2-W075N-HS47-1-FW
  • HDS03.2W075N-HS47-01-FW
  • HDS03.2-W075NHS47-01-FW
  • HDS03.2W075NHS47-01-FW
  • HDS03.2-W075N-HS4701-FW

Frequently Asked Questions about HDS03.2-W075N-HS47-01-FW:

Q: How is the HDS03.2-W075N-HS47-01-FW drive controller cooled?

A: This model features a built-in internal air blower for cooling.

Q: What command communication interface is available on the HDS03.2-W075N-HS47-01-FW?

A: The HDS03.2-W075N-HS47-01-FW supports SERCOS for its command communication interface.

Q: What is the rated current of the HDS03.2-W075N-HS47-01-FW drive controller?

A: The rated current for this drive controller is 75 A, supporting applications that require high current capacity.

Q: Which controller family does the HDS03.2-W075N-HS47-01-FW belong to?

A: This drive controller belongs to the DIAX04 controller family.

Q: What version is the HDS03.2-W075N-HS47-01-FW drive controller?

A: The version of this drive controller is 2, indicating its hardware and feature set.


Internal Product Review

  • ‘‘The HDS03.2-W075N-HS47-01-FW is a Bosch Rexroth Indramat HDS Drive Controller from the DIAX04 family, engineered for precise motion control with a 75 A rated current and SERCOS command communication interface. Its built-in internal air blower ensures effective cooling, supporting reliable performance in demanding automation environments. This controller stands out for robust operation and seamless integration into advanced drive systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo