HDS02.2-W040N-HA13-01-FW Bosch Rexroth Indramat
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
3 Minutes
10 Seconds
The Bosch Rexroth Indramat HDS02.2-W040N-HA13-01-FW is a drive controller from the HDS Drive Controllers series. It features a rated current of 40 Amps and an analog command communication interface. This controller has a built-in internal air blower for cooling and an IP10 protection category.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HDS02.2-W040N-HA13-01-FW drive controller is manufactured by Bosch Rexroth Indramat and is supplied as part of the HDS Drive Controllers series in the DIAX04 family. It is installed in multi-axis cabinets where coordinated drives share common power infrastructure and control signals. The controller receives reference values from a motion control system and regulates its power stage so that connected servo motors follow the required speed or torque profiles in automated production equipment during changing load conditions.
This controller exchanges setpoints through an analog interface, allowing simple voltage or current commands from legacy or PLC-based motion sources. During operation, it can deliver a continuous output of 40 A, so the drive can support substantial dynamic torque without exceeding its current rating. Heat produced by the power section is removed by a built-in air blower, eliminating the need for external cooling ducts inside the cabinet. Reliable electronics function is maintained when the ambient remains between +5 to +45 °C, which supports stable operation in climate-controlled industrial enclosures. Windings, bus bars, and isolation gaps use an insulation system rated to Class C, so the materials can tolerate elevated operating temperatures during continuous use.
The housing carries a protection level of IP10, so only basic guarding against accidental contact is provided and the unit must be installed inside an enclosure. Continuous performance is available up to an installation height of 1000 m above sea level, and reduced air density above that height can limit convective cooling. If cabinet air reaches +55 °C, the controller must be derated to limit thermal stress during heavy duty cycles. For transport and storage, the components tolerate temperatures from -30 to +85 °C without damage, which allows the unit to be kept in unconditioned warehouse spaces before installation.
Frequently Asked Questions about HDS02.2-W040N-HA13-01-FW:
Q: What type of command communication interface does the HDS02.2-W040N-HA13-01-FW use?
A: The HDS02.2-W040N-HA13-01-FW features an analog command communication interface.
Q: How is the HDS02.2-W040N-HA13-01-FW drive controller cooled?
A: This model is equipped with a built-in internal air blower for cooling.
Q: What is the rated current for the HDS02.2-W040N-HA13-01-FW drive controller?
A: The HDS02.2-W040N-HA13-01-FW supports a rated current of 40 A.
Q: Which insulation classification does the HDS02.2-W040N-HA13-01-FW follow?
A: It is classified under insulation class C as per DIN VDE 0110 standards.
Q: What is the permissible ambient temperature range for the HDS02.2-W040N-HA13-01-FW?
A: This controller operates reliably in ambient temperatures from +5°C to +45°C.