4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HDS02.1-W040N-HS62-01-FW Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.4 (51 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
6 Minutes 11 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HDS02.1-W040N-HS62-01-FW is part of the HDS Drive Controllers series and belongs to the DIAX04 controller family. It features a SERCOS command communication interface and a built-in internal air blower for cooling. The drive controller has a rated current of 40 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDS02.1-W040N-HS62-01-FW drive controller is produced by Bosch Rexroth Indramat as part of the HDS Drive Controllers series. Designed for multi-axis automation, the unit converts DC bus energy into regulated three-phase output so servo and spindle motors receive precise torque and speed commands. It functions in conjunction with a shared supply module and feedback devices to coordinate motion sequences across packaging, printing, and material-handling lines.

Communication with the drive is executed over the SERCOS fiber-optic network; this deterministic interface carries set-point, status, and diagnostic data in real time between the controller and a central motion card. Continuous motor current is limited to 40 A, a rating that determines the maximum rms phase current the power stage can deliver without thermal derating. Cooling is handled by a Built-in Internal Air Blower, which draws cabinet air through the heatsink to maintain semiconductor junction temperatures under load. The controller is part of the DIAX04 automation platform, allowing it to slot next to supply and auxiliary modules that share the same DC bus and mechanical footprint. Hardware generation is identified as Line 02, indicating the second release of this housing and power topology.

Firmware coordination is marked as Version 1, meaning the operating microcode, parameter structure, and diagnostic messages correspond to the initial software build for this hardware. As an HDS Drive Controller, the unit accepts plug-in firmware cards so application-specific functions can be updated without changing the power electronics. The design is released exclusively by Bosch Rexroth Indramat, and integration is simplified because mechanical dimensions, field-bus routing, and mounting rails match the wider HDS Drive Controllers family. There are no alternate hardware options, so the published configuration stands as the reference for spare part replacement.

Command Communication Interface
SERCOS
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Installation elevation
1000 M above sea level
Insulation classification
C as per DIN VDE 0110
Line
02
Maximum permissible ambient temperature de-rated
+55° C
Other Versions
None
Permissible ambient temperature range
+5 ... +45° C
Product Type
HDS Drive Controller
Protection category
IP 10 per DIN 40 050
Rated Current
40 A
Storage and transport temperature
-30 ... +85° C
Version
1
  • HDS 02.1-W040N-HS62-01-FW
  • HDS02-1-W040N-HS62-01-FW
  • HDS02.1-W040N-HS62-01
  • HDS021W040NHS6201FW
  • HDS2.1-W040N-HS62-01-FW
  • HDSO2.1-W040N-HS62-01-FW
  • hds02.1-w040n-hs62-01-fw
  • HDS2.1-W4N-HS62-1-FW
  • hds021w040nhs6201fw
  • HD502.1-W040N-HS62-01-FW
  • HDS0Z.1-W040N-HS62-01-FW
  • HDS02.I-W040N-HS62-01-FW
  • HDS02.1-WO40N-HS62-01-FW
  • HDS02.1-W04ON-HS62-01-FW
  • HDS02.1-W040N-H562-01-FW
  • HDS02.1-W040N-HSG2-01-FW
  • HDS02.1-W040N-HS6Z-01-FW
  • HDS02.1-W040N-HS62-O1-FW
  • HDS02.1-W040N-HS62-0I-FW
  • HD5OZ.I-WO4ON-H5GZ-OI-FW
  • HDS02.1-W40N-HS62-01-FW
  • HDS02.1-W04N-HS62-01-FW
  • HDS02.1-W040N-HS62-1-FW

Frequently Asked Questions about HDS02.1-W040N-HS62-01-FW:

Q: What type of command communication interface does the HDS02.1-W040N-HS62-01-FW use?

A: The HDS02.1-W040N-HS62-01-FW utilizes a SERCOS command communication interface for reliable digital control connectivity.

Q: What cooling method is used in the HDS02.1-W040N-HS62-01-FW drive controller?

A: This drive controller features a built-in internal air blower for effective cooling during operation.

Q: What is the rated current of the HDS02.1-W040N-HS62-01-FW drive controller?

A: The rated current for the HDS02.1-W040N-HS62-01-FW is 40 A, allowing it to handle high power requirements.

Q: Which controller family is the HDS02.1-W040N-HS62-01-FW a part of?

A: The HDS02.1-W040N-HS62-01-FW belongs to the DIAX04 controller family.

Q: What line and version is the HDS02.1-W040N-HS62-01-FW drive controller?

A: This model is part of Line 02 and is manufactured in version 1.


Internal Product Review

  • ‘‘The HDS02.1-W040N-HS62-01-FW is an HDS Drive Controller from Bosch Rexroth Indramat, designed for the DIAX04 family with SERCOS command communication interface. Its built-in internal air blower provides efficient cooling, while the 40 A rated current supports demanding automation tasks. This model is well-suited for high-performance industrial drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo