4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

HDS02.1-W040N-HA15-01-FW Bosch Rexroth Indramat

No Tariffs On US Orders
  • Rated 4.4 (32 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
3 Minutes 59 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HDS02.1-W040N-HA15-01-FW is part of the HDS Drive Controllers series and designed for use in the DIAX04 controller family. This drive controller supports a rated current of 40 Amps and uses a built-in internal air blower for cooling. It features an analog command communication interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDS02.1-W040N-HA15-01-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HDS Drive Controllers series. It is intended to sit in a DIAX04 automation rack and translate motion commands from higher-level NC or PLC equipment into regulated three-phase power, letting connected servo axes follow precise speed and torque profiles in industrial machinery. This arrangement places the unit between the machine control and the motor, where it handles the power conversion needed for controlled axis movement during production.

The controller exchanges setpoints and feedback through an analog command channel, making it compatible with legacy motion cards that output voltage references. It belongs to the DIAX04 family, so it shares the general platform layout used in multi-axis installations. Thermal energy is removed by a built-in air blower; this integrated fan pulls cabinet air across the heat sink and keeps the module within its operating limits without external ducting. The power stage supplies up to 40 A of continuous output current, which limits the continuous load the connected motor can draw from the controller. A housing rating of IP10 helps prevent accidental contact with live parts, but the unit still requires installation inside a closed electrical cabinet. Reliable operation is permitted at ambient temperatures from +5 to +45 °C, so additional cabinet cooling is only required when the surrounding air rises above that range.

If higher enclosure temperatures are unavoidable, the device may still run at a derated ceiling of +55 °C by reducing output current. Installation is permitted at elevations up to 1000 m above sea level without changing those thermal limits, because airflow from the internal blower remains adequate at that height. The insulation system meets class C per DIN VDE 0110, and the unit is line 02 and version 1. It also tolerates non-operating storage or transport temperatures from -30 to +85 °C, which supports warehousing and shipment before installation.

Command Communication Interface
ANALOG
Controller Family
DIAX04
Cooling Method
Built-in Internal Air Blower
Installation elevation
1000 M above sea level
Insulation classification
C as per DIN VDE 0110
Line
02
Maximum permissible ambient temperature de-rated
+55° C
Other Versions
None
Permissible ambient temperature range
+5 ... +45° C
Product Type
HDS Drive Controller
Protection category
IP 10 per DIN 40 050
Rated Current
40 A
Storage and transport temperature
-30 ... +85° C
Version
1
  • HDS 02.1-W040N-HA15-01-FW
  • HDS02-1-W040N-HA15-01-FW
  • HDS02.1-W040N-HA15-01
  • HDS021W040NHA1501FW
  • HDS2.1-W040N-HA15-01-FW
  • HDSO2.1-W040N-HA15-01-FW
  • hds02.1-w040n-ha15-01-fw
  • HDS2.1-W4N-HA15-1-FW
  • hds021w040nha1501fw
  • HD502.1-W040N-HA15-01-FW
  • HDS0Z.1-W040N-HA15-01-FW
  • HDS02.I-W040N-HA15-01-FW
  • HDS02.1-WO40N-HA15-01-FW
  • HDS02.1-W04ON-HA15-01-FW
  • HDS02.1-W040N-HAI5-01-FW
  • HDS02.1-W040N-HA1S-01-FW
  • HDS02.1-W040N-HA15-O1-FW
  • HDS02.1-W040N-HA15-0I-FW
  • HD5OZ.I-WO4ON-HAIS-OI-FW
  • HDS02.1-W40N-HA15-01-FW
  • HDS02.1-W04N-HA15-01-FW
  • HDS02.1-W040N-HA15-1-FW
  • HDS02.1W040N-HA15-01-FW

Frequently Asked Questions about HDS02.1-W040N-HA15-01-FW:

Q: What command communication interface is available on the HDS02.1-W040N-HA15-01-FW drive controller?

A: This model uses an analog command communication interface for signal input and control.

Q: How is the HDS02.1-W040N-HA15-01-FW drive controller cooled?

A: The HDS02.1-W040N-HA15-01-FW is equipped with a built-in internal air blower for cooling.

Q: What is the rated current of the HDS02.1-W040N-HA15-01-FW drive controller?

A: This drive controller is rated for continuous operation at 40 A.

Q: What controller family does the HDS02.1-W040N-HA15-01-FW belong to?

A: The HDS02.1-W040N-HA15-01-FW belongs to the DIAX04 controller family.

Q: What line is the HDS02.1-W040N-HA15-01-FW drive controller part of?

A: This model is from line 02 of the HDS Drive Controllers series.


Internal Product Review

  • ‘‘The HDS02.1-W040N-HA15-01-FW is a robust HDS drive controller from Bosch Rexroth Indramat, designed for the DIAX04 family and equipped with an analog command communication interface. It features a built-in internal air blower for cooling and supports a rated current of 40 A, making it well-suited for demanding motion control environments. Overall, this unit offers reliable performance and efficient heat management within industrial automation systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo