The Bosch Rexroth Indramat HDC01.1-A200N-IB02-01-FW is part of the HDC DuraDrive Controllers series and has a mass of 40 kilograms. It supports a continuous current of 100 amps at 4 kHz and a peak current of 200 amps, with a maximum DC bus power of 15 kilowatts at 400 volts. This controller features a protection rating of IP20 and is rated for a maximum installation altitude of 2000 meters.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDC01.1-A200N-IB02-01-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HDC DuraDrive Controllers series. It rectifies incoming line power, buffers it on a shared DC link, and manages braking energy so connected servo axes can accelerate or stop without disturbing the mains supply. In automated lines, packaging cells, and material-handling stations, the unit provides regulated power that allows multiple inverters to operate from a common bus while keeping voltage and thermal loading within normal operating limits.

The electrical section includes several continuous-duty ratings. The internal bleeder can dissipate 1.5 kW continuously, which helps protect the DC bus during routine deceleration. At a switching frequency of 4 kHz, the controller supplies 100 A of armature current, while at 8 kHz the limit is 68 A because switching losses increase. Short-term torque demand is supported by a pulse current of 200 A. A storage capacitance of 4.7 mF stabilizes the 400 V DC link and supports delivery of up to 15.0 kW to downstream drives. Additional electrical values include a 7.0 A charging current during power-up, a 24 Ω soft-start resistor to limit inrush, and surge suppression that tolerates 40 V of control overvoltage for 1 ms.

During heavy braking, the bleeder can momentarily absorb 115 kW, and the thermal system can take in 60 kWs of energy before reaching its limit. The inverter stages can modulate up to 400 Hz, which supports high-speed spindles or linear motor operation. Installation is permitted up to 2000 m altitude, with ambient humidity up to 95% as long as condensation is avoided, and the housing weighs 40 kg. An enclosure rating of IP20 indicates finger-safe terminals, so the controller must be installed inside a closed electrical cabinet for protection from dust and moisture.

Continuous Bleeder Power
1.5 kW
Continuous Current At 4 Khz
100 A
Continuous Current At 8 Khz
68 A
Dc Bus Capacitance
4.7 mF
Mass
40 kg
Max Charging Current
7.0 A
Max Control Overvoltage
40 V For 1 ms
Max Dc Bus Power At 400 V
15.0 kW
Max Energy Dissipation
60 kWs
Max Installation Altitude
2000 m
Max Output Frequency
400 Hz
Max Relative Humidity
95%
Peak Bleeder Power
115 kW
Peak Current 1
200 A
Protection Rating
IP20
Soft-start Resistor
24 Ohm
  • HDC01 1 A200N IB02 01 FW
  • HDC011A200NIB0201FW
  • hdc01.1-a200n-ib02-01-fw
  • HDC1.1-A200N-IB02-01-FW

Frequently Asked Questions about HDC01.1-A200N-IB02-01-FW:

Q: What is the continuous current rating of the HDC01.1-A200N-IB02-01-FW at 4 kHz?

A: The HDC01.1-A200N-IB02-01-FW supports a continuous current of 100 A at 4 kHz switching frequency.

Q: What is the maximum output frequency provided by the HDC01.1-A200N-IB02-01-FW?

A: This drive controller has a maximum output frequency of 400 Hz.

Q: What is the protection rating of the HDC01.1-A200N-IB02-01-FW drive controller?

A: The HDC01.1-A200N-IB02-01-FW offers a protection rating of IP20, indicating limited protection against dust but no protection from water.

Q: What is the maximum installation altitude for the HDC01.1-A200N-IB02-01-FW?

A: A maximum installation altitude of 2000 m is specified for this controller.

Q: What value soft-start resistor does the HDC01.1-A200N-IB02-01-FW include?

A: The controller's soft-start resistor is rated at 24 Ohms, helping manage inrush current during startup.


Internal Product Review

  • ‘‘The HDC01.1-A200N-IB02-01-FW is a Bosch Rexroth Indramat DuraDrive controller built for high-demand drive service, with 100 A continuous current at 4 kHz and 200 A peak current. IP20 protection and 15.0 kW maximum DC bus power at 400 V support dependable cabinet integration and strong power handling. A very capable controller for motion systems requiring stable output and confident current reserve.’’