4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HDC01.1-A040N-SE01-01-FW Bosch Rexroth Indramat

MPN: R911291254

No Tariffs On US Orders
  • Rated 4.5 (55 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
5 Minutes 4 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HDC01.1-A040N-SE01-01-FW is part of the HDC DuraDrive Controllers series and comes with a rated current of 40 Amps. This controller uses natural convection cooling, features an IP20 protection type, and supports a SERCOS interface. It measures 420 mm in height, 250 mm in depth, weighs 12 kilograms, and has a peak bleeder power of 11.5 kW.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HDC01.1-A040N-SE01-01-FW drive controller belongs to the HDC DuraDrive Controllers series from Bosch Rexroth Indramat. It forms the central regulating element between an industrial power supply and the servo motor, commanding torque, velocity, and position while managing regenerated energy on the DC link. Installed inside electrical cabinets, the unit contributes to automated assembly cells, gantry axes, and packaging equipment by supplying controlled three-phase power and real-time communication to each connected drive module.

During operation, the bleeder dissipates 0.075 kW of regenerative energy to hold the DC bus voltage steady during deceleration. For brief braking events, it tolerates up to 11.5 kW, giving headroom for emergency stops. The power stage delivers a continuous current of 40 A, so motors with similar demand can be driven without derating. Only 25 W of auxiliary power is needed to run the control electronics, minimizing standby draw. A capacitor bank of 0.585 mF smooths the DC link and supports transient loads. Natural convection cools the heat sink, and a 60-ohm soft-start resistor limits inrush when the bus is charged.

The power stage can modulate carrier frequencies up to 400 Hz, supporting high-speed spindles and finely stepped servo profiles. Command and feedback data travel over the SERCOS interface, ensuring synchronized positioning across multi-axis networks. The enclosure has an IP20 protection category, so it is finger-safe but not sealed and must be kept in a closed cabinet where ambient humidity does not exceed 95% non-condensing. At 12 kg, the controller is intended for cabinet mounting, and its 420 mm height, 105 mm width, and 250 mm depth fit common drive bays. The design can absorb a cumulative 5 kWs of braking energy without exceeding component limits.

Continuous Bleeder Power
0.075 kW
Control Power Input
25 W
Cooling Mode
Natural Convection
Dc Bus Capacitance
0.585 mF
Depth
250 mm
Height
420 mm
Interface
SERCOS
Mass
12 kg
Max Energy Dissipation
5 kWs
Max Output Frequency
400 Hz
Max Relative Humidity
95%
Peak Bleeder Power
11.5 kW
Rated Current
40 A
Soft-start Resistor
60 Ohm
Type Of Protection
IP20
Width
105 mm
  • HDC01 1 A040N SE01 01 FW
  • HDC011A040NSE0101FW
  • hdc01.1-a040n-se01-01-fw
  • HDC1.1-A040N-SE01-01-FW

Frequently Asked Questions about HDC01.1-A040N-SE01-01-FW:

Q: What communication interface does the HDC01.1-A040N-SE01-01-FW controller use?

A: The HDC01.1-A040N-SE01-01-FW operates with an interface that supports SERCOS communication.

Q: What cooling method is used by the HDC01.1-A040N-SE01-01-FW?

A: This drive controller features natural convection cooling and does not require active fans.

Q: What is the rated current output of the HDC01.1-A040N-SE01-01-FW?

A: The HDC01.1-A040N-SE01-01-FW can deliver a rated current of 40 A.

Q: What is the protection rating for the HDC01.1-A040N-SE01-01-FW?

A: Its type of protection is rated at IP20, providing limited protection against solid objects.

Q: What is the maximum output frequency supported by the HDC01.1-A040N-SE01-01-FW?

A: The controller supports a maximum output frequency of 400 Hz for fast drive applications.


Internal Product Review

  • ‘‘The HDC01.1-A040N-SE01-01-FW is a Bosch Rexroth Indramat DuraDrive controller with a 40 A rated current and SERCOS interface. Natural convection cooling and IP20 protection support dependable cabinet integration in demanding automation service. A 400 Hz maximum output frequency and 11.5 kW peak bleeder power make the unit a strong choice for responsive drive control.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo