4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911401589

No Tariffs On US Orders
  • Rated 4.5 (39 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW is an HCS IndraDrive Controller with a device peak current of 18 Amps and a MultiEthernet communication interface. This HCS01 series drive controller features internal air cooling through an integrated blower and an IP20 rating. It operates on 3-phase AC mains voltage from 110 to 230 Volts with a 10 percent tolerance and is equipped with an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW is a single-axis drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It serves as the power conversion and closed-loop regulation stage between a machine’s control section and its servomotor, supplying commanded current while supervising protective functions. In industrial automation cells, the unit provides velocity, torque, and position control so that packaging stations, small conveyors, or handling modules remain synchronized with the master PLC during starts, stops, and speed changes. This arrangement lets the machine control send motion commands to the drive while the controller handles current regulation and protective responses locally.

For network connectivity, the controller offers a MultiEthernet port that handles real-time fieldbus protocols without additional option cards. Its power stage accepts a three-phase mains supply of 3 × AC 110…230 V ±10% and can deliver a device peak output of 18 A during acceleration or braking peaks. Thermal management relies on internal air cooling through a built-in blower, eliminating the need for external fans or liquid circuits inside the cabinet. The housing has an IP20 rating, so it requires installation in an enclosed electrical panel.

The electronics use Design Version 1 and operate with Control Section “BASIC”. Motor feedback is processed through the integrated IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, while the second feedback slot remains empty to keep the layout limited to one feedback channel. The internal power interface supports infeeding and fed operation, allowing the module to share regenerative DC-bus energy with neighboring axes. That arrangement is suitable for systems that return braking energy to the shared DC bus instead of dissipating it at each axis.

Communication Interface
MultiEthernet
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A02AETECNNS4NNFW
  • HCS01 1E W0018 A 02 A ET EC NN S4 NN FW
  • hcs01.1e-w0013-a-02-b-et-ec-ec-s4-nn-fw
  • HCS1.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW support?

A: This unit is equipped with a MultiEthernet communication interface for network integration.

Q: How is the HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW cooled?

A: The HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW utilizes internal air cooling via an integrated blower.

Q: What is the peak current capability of the HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW?

A: This controller can handle a device peak current of 18 A.

Q: What mains voltage range is supported by the HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW?

A: The HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW operates with a mains voltage of 3 x AC 110 to 230 V ±10%.

Q: What level of environmental protection does the HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW provide?

A: This model offers an IP20 rating, which means it is protected against solid objects greater than 12 mm but not against liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-A-ET-EC-NN-S4-NN-FW is an HCS drive controller that stands out for straightforward MultiEthernet integration. Internal blower cooling and an 18 A peak current support stable thermal performance and responsive drive operation. IP20 protection makes this controller a strong fit for organized cabinet installations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo