HCS04.2E-W0390-N-06-NNNN Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911329245
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS04.2E-W0390-N-06-NNNN is part of the HCS IndraDrive Controllers series and has a maximum output frequency of 300 Hz with a nominal clock frequency of 4 kHz. This drive controller uses air cooling through an integrated blower and is designed for vertical mounting with IP20 top protection and IP31 front protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS04.2E-W0390-N-06-NNNN is a drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. In multi-axis automation cells, it regulates power modules and motors while coordinating torque and speed loops from higher-level PLC setpoints. By integrating an infeeding power supply unit, the device supplies energy to connected axes and returns regenerative power to the DC bus, supporting efficient motion sequences in packaging, printing, and material-handling lines.
The controller uses internal air cooling through an integrated blower, so an onboard fan pulls cabinet air through the heat sink and removes the need for external ducts. A control loop updates at 4 kHz, and this nominal clock frequency sets the PWM timing that drives the IGBTs and influences current ripple. For motor excitation, it can deliver an output frequency of up to 300 Hz, allowing high-speed spindle or servo operation. Protection against line transients falls under Category III of the overvoltage scale, which suits fixed industrial wiring. During short overload events, Power 1 can rise to 50%/65% above nominal for 60 s or 2 s respectively, while a second channel permits 20%/35% overrating. The PELV insulation concept keeps control circuits at a safe potential relative to protective earth, and the unit is intended for vertical mounting to maintain the internal airflow path. Communication hardware is not specified, so fieldbus expansion can be selected separately.
Ingress protection varies by location on the housing: the bottom is open at IP00, the front and sides meet IP31, and the top edge attains IP20. These enclosure levels help determine cabinet placement so falling debris or accidental contact does not interfere with operation. The unit tolerates relative humidity up to 95% without condensation when properly derated, and its Class 1 protection class uses a grounded conductive enclosure.
Frequently Asked Questions about HCS04.2E-W0390-N-06-NNNN:
Q: What cooling method is used in the HCS04.2E-W0390-N-06-NNNN drive controller?
A: The HCS04.2E-W0390-N-06-NNNN drive controller features internal air cooling using an integrated blower for temperature management.
Q: What type of insulation is used in the HCS04.2E-W0390-N-06-NNNN drive controller?
A: This controller is equipped with PELV insulation, providing protection for both personnel and low-voltage circuits.
Q: What is the maximum output frequency of the HCS04.2E-W0390-N-06-NNNN drive controller?
A: The HCS04.2E-W0390-N-06-NNNN supports a maximum output frequency of 300 Hz.
Q: What is the recommended mounting orientation for the HCS04.2E-W0390-N-06-NNNN drive controller?
A: The HCS04.2E-W0390-N-06-NNNN is designed for vertical mounting orientation.
Q: What level of protection is provided by the front and lateral sides of the HCS04.2E-W0390-N-06-NNNN controller?
A: This drive controller provides IP31 protection at the front and lateral sides, offering basic protection against solid objects greater than 2.5 mm and limited ingress of liquids.